MX25U4035
MX25U8035
RECOMMENDED OPERATING CONDITIONS
At Device Power-Up
AC timing illustrated in Figure A is recommended for the supply voltages and the control signals at device power-up.
If the timing in the figure is ignored, the device may not operate correctly.
Figure A. AC Timing at Device Power-Up
VCC(min)
VCC
GND
tVSL
tSHSL
tVR
CS#
tCHSL
tSLCH
tCHSH
tSHCH
SCLK
tDVCH
tCHCL
tCHDX
tCLCH
MSB IN
LSB IN
SI
High Impedance
SO
Symbol
tVR
tVSL
Parameter
VCC Set Up Time
VCC (min) to CS# low
Notes
Min.
20
50
Max.
500000
Unit
us/V
us
1
Notes :
1. Sampled, not 100% tested.
2. For AC spec tCHSL, tSLCH, tDVCH, tCHDX, tSHSL, tCHSH, tSHCH, tCHCL, tCLCH in the figure, please refer to
"AC CHARACTERISTICS" table.
P/N: PM1394
REV. 1.0, MAR. 09, 2009
47