欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAX706MJA/883B 参数 Datasheet PDF下载

MAX706MJA/883B图片预览
型号: MAX706MJA/883B
PDF下载: 下载PDF文件 查看货源
内容描述: [Power Supply Management Circuit, Fixed, 1 Channel, CMOS, CDIP8, CERAMIC, DIP-8]
分类和应用:
文件页数/大小: 5 页 / 31 K
品牌: MAXIM [ MAXIM INTEGRATED PRODUCTS ]
 浏览型号MAX706MJA/883B的Datasheet PDF文件第1页浏览型号MAX706MJA/883B的Datasheet PDF文件第2页浏览型号MAX706MJA/883B的Datasheet PDF文件第3页浏览型号MAX706MJA/883B的Datasheet PDF文件第4页  
QUALITY ASSURANCE
Sampling and inspection procedures shall be in accordance with MIL-Prf-38535, Appendix A as specified in Mil-
Std-883.
Screening shall be in accordance with Method 5004 of Mil-Std-883. Burn-in test Method 1015:
1. Test Condition, A, B, C, or D.
2. TA = +125°C minimum.
3. Interim and final electrical test requirements shall be specified in Table 2.
Quality conformance inspection shall be in accordance with Method 5005 of Mil-Std-883, including Groups A, B,
C, and D inspection.
Group A inspection:
1. Tests as specified in Table 2.
2. Selected subgroups in Table 1, Method 5005 of Mil-Std-883 shall be omitted.
Group C and D inspections:
a. End-point electrical parameters shall be specified in Table 1.
b. Steady-state life test, Method 1005 of Mil-Std-883:
1. Test condition A, B, C, D.
2. TA = +125°C, minimum.
3. Test duration, 1000 hours, except as permitted by Method 1005 of Mil-Std-883.
TABLE 2.
ELECTRICAL TEST REQUIREMENTS
Mil-Std-883 Test Requirements
Subgroups
per Method 5005, Table 1
1
1*, 2, 3, 9, 10, 11
1, 2, 3, 9, 10, 11
1, 9
Interim Electric Parameters
Method 5004
Final Electrical Parameters
Method 5005
Group A Test Requirements
Method 5005
Group C and D End-Point Electrical Parameters
Method 5005
*
PDA applies to Subgroup 1 only.
----------------------------
Electrical Characteristics of MAX705/706/707/708/813L/883B
for /883B and SMD 5962-93267
19-0216
Page 6 of
Rev. C
7