±±1°C ꢀMꢁusꢂ°oꢃpatiꢄle ꢅeꢃote/ꢆocal eꢃperature  
ꢀensors with Overteꢃperature Alarꢃs  
Table 2. Data Format (Two's Complement)  
Table 3. Extended Resolution Register  
FRACTIONAL  
CONTENTS OF  
DIGITAL OUTPUT  
TEMPERATURE  
EXTENDED REGISTER  
TEMP (°C)  
MAX6658  
MAX6659  
MAX6657  
0.000  
0.125  
0.250  
0.375  
0.500  
0.625  
0.750  
0.875  
000X XXXX  
001X XXXX  
010X XXXX  
011X XXXX  
100X XXXX  
101X XXXX  
110X XXXX  
111X XXXX  
130.00  
127.00  
126.00  
25  
0 111 1111  
0 111 1111  
0 111 1111  
0 001 1001  
0 000 0000  
1 000 0000  
1 000 0000  
1 000 0000  
0 111 1111  
0 111 1111  
0 111 1111  
0 001 1001  
0 000 0000  
1 111 1111  
1 110 0111  
1 100 1001  
0.00  
-1  
-25  
Note: Extended resolution applies only for conversion rates of  
4Hz and slower.  
-55  
Diode Fault  
(Short or Open)  
1 000 0000  
1 000 0000  
Alert ꢅesponse Address  
The SMBus Alert Response interrupt pointer provides  
quick fault identification for simple slave devices that  
lack the complex, expensive logic needed to be a bus  
master. Upon receiving an ALERT interrupt signal, the  
host master can broadcast a Receive Byte transmission  
to the Alert Response slave address (0001100). Then,  
any slave device that generated an interrupt attempts  
to identify itself by putting its own address on the bus  
(Table 8).  
Alarꢃ ꢇhreshold ꢅegisters  
Four registers store ALERT threshold valuesone high-  
temperature (T ) and one low-temperature (T  
register each for the local and remote channels. If  
either measured temperature equals or exceeds the  
corresponding ALERT threshold value, the ALERT out-  
put is asserted.  
)
LOW  
HIGH  
The POR state of both ALERT T  
0110 or +70°C and the POR state of T  
1100 1001 or -55°C.  
registers is 0100  
LOW  
HIGH  
The Alert Response can activate several different slave  
devices simultaneously, similar to the I2C General Call.  
If more than one slave attempts to respond, bus arbitra-  
tion rules apply, and the device with the lower address  
code wins. The losing device does not generate an  
acknowledge and continues to hold the ALERT line low  
until cleared. (The conditions for clearing an alert vary,  
depending on the type of slave device.) Successful  
completion of the Alert Response protocol clears the  
interrupt latch, provided the condition that caused the  
alert no longer exists. If the condition still exists, the  
device reasserts the ALERT interrupt at the end of the  
next conversion.  
registers is  
Four additional registers store remote and local alarm  
threshold data corresponding to the OVERT1 and  
OVERT2 (MAX6659 only) outputs. The values stored in  
these registers are high-temperature thresholds. If any  
one of the measured temperatures equals or exceeds  
the corresponding alarm threshold value, an OVERT  
output is asserted. The POR state of the OVERT thresh-  
old is 0101 0101 or +85°C.  
Alert Interrupts  
An ALERT interrupt occurs when the internal or external  
temperature reading exceeds a high or low tempera-  
ture limit (user programmed) or when the remote diode  
is disconnected (for continuity fault detection). The  
ALERT interrupt output signal is latched and can be  
cleared only by either reading the Status register or by  
successfully responding to an Alert Response address.  
In both cases, the alert is cleared even if the fault con-  
dition still exists, but is reasserted at the end of the next  
conversion. The interrupt does not halt automatic con-  
versions. The interrupt output pin is open-drain so that  
multiple devices can share a common interrupt line.  
The interrupt rate never exceeds the conversion rate.  
OVERT Overteꢃperature  
Alarꢃ/Warning Outputs  
OVERT1 and OVERT2 (MAX6659 only) are asserted  
when the temperature rises to a value programmed in  
the appropriate threshold register. They are deasserted  
when the temperature drops below this threshold minus  
the hysteresis. An OVERT output can be used to acti-  
vate a cooling fan, send a warning, or trigger a system  
shutdown to prevent component damage. The HYST  
byte sets the amount of hysteresis for both OVERT out-  
puts. The data format for the HYST byte is the same for  
the other temperature registers (Table 2).  
______________________________________________________________________________________ 11