欢迎访问ic37.com |
会员登录 免费注册
发布采购

DS18B20-PAR_07 参数 Datasheet PDF下载

DS18B20-PAR_07图片预览
型号: DS18B20-PAR_07
PDF下载: 下载PDF文件 查看货源
内容描述: 1 - Wire寄生供电数字温度计 [1-Wire Parasite-Power Digital Thermometer]
分类和应用:
文件页数/大小: 19 页 / 207 K
品牌: MAXIM [ MAXIM INTEGRATED PRODUCTS ]
 浏览型号DS18B20-PAR_07的Datasheet PDF文件第6页浏览型号DS18B20-PAR_07的Datasheet PDF文件第7页浏览型号DS18B20-PAR_07的Datasheet PDF文件第8页浏览型号DS18B20-PAR_07的Datasheet PDF文件第9页浏览型号DS18B20-PAR_07的Datasheet PDF文件第11页浏览型号DS18B20-PAR_07的Datasheet PDF文件第12页浏览型号DS18B20-PAR_07的Datasheet PDF文件第13页浏览型号DS18B20-PAR_07的Datasheet PDF文件第14页  
DS18B20-PAR  
transmitted least significant bit first. All three bytes MUST be written before the master issues a reset, or  
the data may be corrupted.  
READ SCRATCHPAD [BEh]  
This command allows the master to read the contents of the scratchpad. The data transfer starts with the  
least significant bit of byte 0 and continues through the scratchpad until the 9th byte (byte 8 – CRC) is  
read. If only part of the scratchpad contents is required, the master may issue a reset to terminate reading  
at any time.  
COPY SCRATCHPAD [48h]  
This command copies the contents of the scratchpad TH, TL and configuration registers (bytes 2, 3 and 4)  
to EEPROM. Within 10 μs (max) after this command is issued the master must enable a strong pullup on  
the 1-Wire bus for at least 10 ms as described in the PARASITE POWER section.  
RECALL E2 [B8h]  
This command recalls the alarm trigger values (TH and TL) and configuration data from EEPROM and  
places the data in bytes 2, 3, and 4, respectively, in the scratchpad memory. The master device can issue  
“read time slots” (see the 1-WIRE BUS SYSTEM section) following the Recall E2 command and the  
DS18B20-PAR will indicate the status of the recall by transmitting 0 while the recall is in progress and  
1 when the recall is done. The recall operation happens automatically at power-up, so valid data is  
available in the scratchpad as soon as power is applied to the device.  
DS18B20-PAR Function Command Set Table 4  
1-Wire Bus Activity  
Command  
Convert T  
Description  
Protocol After Command is Issued Notes  
TEMPERATURE CONVERSION COMMANDS  
Initiates temperature  
conversion.  
44h  
None  
1
MEMORY COMMANDS  
Read Scratchpad  
Reads the entire scratchpad  
including the CRC byte.  
BEh  
DS18B20-PAR transmits up  
to 9 data bytes to master.  
Master transmits 3 data  
bytes to DS18B20-PAR.  
2
3
Write Scratchpad Writes data into scratchpad  
bytes 2, 3, and 4 (TH, TL, and  
4Eh  
configuration registers).  
Copy Scratchpad Copies TH, TL, and  
configuration register data from  
the scratchpad to EEPROM.  
48h  
None  
1
Recall E2  
Recalls TH, TL, and  
configuration register data from  
EEPROM to the scratchpad.  
B8h  
DS18B20-PAR transmits  
recall status to master.  
NOTES:  
1. The master must enable a strong pullup on the 1-Wire bus during temperature conversions and copies  
from the scratchpad to EEPROM. No other bus activity may take place during this time.  
2. The master can interrupt the transmission of data at any time by issuing a reset.  
3. All three bytes must be written before a reset is issued.  
10 of 19