RTCs with Constant-Voltage Trickle Charger  
5C/DS12R87  
An external 32.768kHz oscillator can also drive the  
LOCAL GROUND PLANE (LAYER 2)  
DS12R885. In this configuration, the X1 pin is connected  
to the external oscillator signal and the X2 pin is left  
unconnected.  
X1  
Clock Accuracy  
The accuracy of the clock is dependent upon the accu-  
CRYSTAL  
X2  
racy of the crystal and the accuracy of the match  
between the capacitive load of the oscillator circuit and  
the capacitive load for which the crystal was trimmed.  
NOTE: AVOID ROUTING SIGNAL LINES  
IN THE CROSSHATCHED AREA  
(UPPER LEFT QUADRANT) OF  
THE PACKAGE UNLESS THERE IS  
A GROUND PLANE BETWEEN THE  
SIGNAL LINE AND THE DEVICE PACKAGE.  
Additional error is added by crystal frequency drift  
caused by temperature shifts. External circuit noise cou-  
GND  
pled into the oscillator circuit can result in the clock run-  
ning fast. Figure 2 shows a typical PC board layout for  
isolation of the crystal and oscillator from noise. Refer to  
Application Note 58: Crystal Considerations with Dallas  
Real-Time Clocks (RTCs) for more detailed information.  
Figure 2. Layout Example  
used by the daylight saving function, so the value 1 is  
defined as Sunday. The date at the end of the month is  
automatically adjusted for months with fewer than 31  
days, including correction for leap years.  
The DS12R887 and DS12CR887 are calibrated at the  
factory to an accuracy of 1 minute per month at  
+25°C during data-retention time for the period tDR  
.
Power-Down/Power-Up  
Considerations  
Before writing the internal time, calendar, and alarm reg-  
isters, the SET bit in Register B should be written to logic  
1 to prevent updates from occurring while access is  
being attempted. In addition to writing the 10 time, calen-  
dar, and alarm registers in a selected format (binary or  
BCD), the data mode bit (DM) of Register B must be set  
to the appropriate logic level. All 10 time, calendar, and  
alarm bytes must use the same data mode. The SET bit  
in Register B should be cleared after the data mode bit  
has been written to allow the RTC to update the time and  
calendar bytes. Once initialized, the RTC makes all  
updates in the selected mode. The data mode cannot be  
changed without reinitializing the 10 data bytes. Tables  
2A and 2B show the BCD and binary formats of the time,  
calendar, and alarm locations.  
The real-time clock continues to operate regardless of  
the V  
input level, and the RAM and alarm memory  
CC  
locations remain nonvolatile. V  
must remain  
BACKUP  
within the minimum and maximum limits when V  
is  
CC  
not applied. When V  
is applied and exceeds V  
CC  
PF  
(power-fail trip point), the device becomes accessible  
after t —if the oscillator is running and the oscillator  
countdown chain is not in reset (Register A). This time  
allows the system to stablize after power is applied. If  
the oscillator is not enabled, the oscillator-enable bit is  
enabled on power-up, and the device becomes imme-  
diately accessible.  
REC  
Time, Calendar, and Alarm  
Locations  
The time and calendar information is obtained by read-  
ing the appropriate register bytes. The time, calendar,  
and alarm are set or initialized by writing the appropri-  
ate register bytes. The contents of the 10 time, calen-  
dar, and alarm bytes can be either binary or  
binary-coded decimal (BCD) format.  
The 24/12 bit cannot be changed without reinitializing the  
hour locations. When the 12-hour format is selected, the  
higher-order bit of the hours byte represents PM when it  
is logic 1. The time, calendar, and alarm bytes are always  
accessible because they are double-buffered. Once per  
second the seven bytes are advanced by one second  
and checked for an alarm condition.  
If a read of the time and calendar data occurs during  
an update, a problem exists where seconds, minutes,  
hours, etc., may not correlate. The probability of read-  
ing incorrect time and calendar data is low. Several  
The day-of-week register increments at midnight, incre-  
menting from 1 through 7. The day-of-week register is  
____________________________________________________________________ 13