MAS6501 CONTROL REGISTER
Table 1. MAS6501 control register bit description
Bit Number
Bit Name
Description
Value
Function
7-6
OSRS(1:0)
Over Sampling Ratio
(OSR) selection
11
01
10
00
0
OSR = 512
OSR = 256
OSR = 128
OSR = 64
No Conversion
Start Conversion
5
4
3
2
1
SCO
PTS
Start Conversion
1
Pressure/Temperature
Selection
Input Signal
Conversion Range
Enable Master Clock
Division
1
0
Pressure configuration
Temperature configuration
325 mV (282 mV linear range)
98 mV (85 mV linear range)
MCLK division enabled
MCLK division disabled
ISCR
1
0
XENMCLKDIV
XOSENABLE
0
1
Enable offset
0
Offset enabled
Offset disabled
+123 mV
1
1
0
0
OSSELECT
Offset value selection
+33 mV
MAS6501 has one control register for configuring
the measurement setup. See table 1 for control
register bit definitions. Control register values are
set via I2C bus.
low, the MCLK division is enabled and the internal
clock frequency fCLK(INT) = fMCLK/2, where
fMCLK is the master clock frequency. When the
XENMCLKDIV bit is high, the MCLK division is
disabled and fCLK(INT) = fMCLK.
First two OSRS bits of the control register define
four selectable over sampling ratios. The higher
OSR the better ADC accuracy but the longer
conversion time.
In the XENMCLKDIV = 1 mode the duty cycle
should be as close to 50 % as possible. In this
mode, the conversion time is made half (see page 3
conversion time values with XENMCLKDIV = 1)
compared to clock speed division mode
XENMCLKDIV = 0 whereas the resolution remains
unchanged. In XENMCLKDIV = 0 mode the
conversion time and also current consumption are
doubled but then the external master clock signal
MCLK does not need to have close to 50% duty
cycle.
The SCO bit controls the A/D conversion. When
SCO = 0, no A/D conversion takes place. When
SCO = 1, the A/D converter turns on and the analog
data is being converted. Then MCLK must be
clocked at least until EOC pin goes high indicating
that conversion has been accomplished.
PTS bit selects between pressure and temperature
measurement. In temperature measurement the
sensor is connected in bridge configuration together
with four integrated resistors (see figure 3 on page 8
and resistors R1, R2, R3 and R4).
XOSENABLE can be used to enable input signal
range offset option. At 1 value no offset is applied
but at 0 value an offset value which is determined
with OSSELECT bit is used.
ISCR selects between two A/D conversion ranges.
OSSELECT selects between two offset values. No
offset
offset
(XOSENABLE=1).
is
applied
if
is
disabled
The XENMCLKDIV bit controls the internal clock
frequency of MAS6501, fCLK(INT). When the bit is
5 (16)