 浏览型号MAS6501BA1WA300的Datasheet PDF文件第1页浏览型号MAS6501BA1WA300的Datasheet PDF文件第3页浏览型号MAS6501BA1WA300的Datasheet PDF文件第4页浏览型号MAS6501BA1WA300的Datasheet PDF文件第5页浏览型号MAS6501BA1WA300的Datasheet PDF文件第6页浏览型号MAS6501BA1WA300的Datasheet PDF文件第7页浏览型号MAS6501BA1WA300的Datasheet PDF文件第8页浏览型号MAS6501BA1WA300的Datasheet PDF文件第9页  
DA6501.001  
27 October 2008  
BLOCK DIAGRAM  
VDD  
S&H  
PI  
NI  
DIG  
INT  
DIG  
FIL  
EOC  
ADC  
SDA  
SCL  
COMMON  
XCLR  
GND  
MCLK  
Figure 1. MAS6501 block diagram  
ABSOLUTE MAXIMUM RATINGS  
All Voltages with Respect to Ground  
Parameter  
Symbol  
Conditions  
Min  
Max  
Unit  
Supply Voltage  
VCC  
During conversion  
No conversion  
- 0.3  
- 0.3  
- 0.3  
3.8  
6.0  
V
Voltage Range for All Pins  
Latchup Current Limit  
VIN + 0.3  
V
ILUT  
For all pins,  
test according to  
- 100  
+ 100  
mA  
Micro Analog Systems  
specification ESQ0141.  
See note below.  
Junction Temperature  
Storage Temperature  
TJmax  
TS  
+ 175  
+125  
°C  
°C  
- 55  
Note: Stresses beyond the values listed may cause a permanent damage to the device. The device may not  
operate under these conditions, but it will not be destroyed.  
Note: This is a CMOS device and therefore it should be handled carefully to avoid any damage by static voltages  
(ESD).  
Note: In latchup testing the supply voltages are connected normally to the tested device. Then pulsed test current is fed  
to each input separately and device current consumption is observed. If the device current consumption increases  
suddenly due to test current pulses and the abnormally high current consumption continues after test current pulses are  
cut off then the device has gone to latch up. Current pulse is turned on for 10 ms and off for 20 ms.  
RECOMMENDED OPERATION CONDITIONS  
Parameter  
Symbol  
Conditions  
Min  
Typ  
Max  
Unit  
Supply Voltage  
VCC  
TA  
2.0  
-20  
2.35  
+25  
3.6  
V
Operating Temperature  
+60  
°C  
The device performance may deteriorate in the long run if the Recommended Operation Conditions limits are continuously exceeded.  