 浏览型号MAS6503CA1WAB05的Datasheet PDF文件第12页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第13页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第14页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第15页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第17页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第18页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第19页浏览型号MAS6503CA1WAB05的Datasheet PDF文件第20页  
DA6503.005  
14 December 2016  
MEASUREMENT CONTROL REGISTER 2 (E3/63HEX  
)
Measurement control register  
configures second half of the measurement settings  
and also starts the measurement. See table 4.  
2
(E3/63HEX  
)
RSENSOR according to sensor resistance is  
important only for the temperature measurement  
mode. See also Temperature Measurement  
Configuration in the Application Information section.  
OSRS bits select over sampling ratio (OSR) setting  
from five options. The OSR selection affects both  
measurement resolution and conversion time. The  
best resolution is achieved at highest OSR setting  
4096 but the conversion time is longest. The fastest  
conversion is achieved at lowest OSR setting 256  
but the achieved resolution is lowest. Typically  
highest OSR setting is used only in the most  
PTS bits select between three measurement  
modes; pressure, temperature and VDD level  
monitoring modes.  
The conversion starts right after writing data byte to  
the Measurement control register 2. Thus to start  
new conversion the measurement configuration  
data has to be written first to Measurement control  
register 1 and after that to the Measurement control  
register 2. To avoid disturbing the running  
measurement the serial communication with  
MAS6503 should be kept idle during conversions.  
The EOC pin goes low when the conversion starts  
and it returns back high when the conversion is  
ready.  
precise  
measurement  
such  
as  
pressure  
measurement. Medium or lowest OSR setting is  
typically sufficient in the temperature measurement.  
The lowest OSR setting can be used in the least  
precision VDD level monitoring measurement.  
RSENSOR bits select sensor resistance from eight  
options from 2.0kΩ up to 10 kΩ. Selecting proper  
Table 4. Measurement control register 2 (E3/63HEX) description  
Bit Number  
Bit Name  
Description  
Value  
Function  
7-5  
OSRS  
Over Sampling Ratio  
(OSR) Selection  
000  
001  
010  
011  
100  
000  
001  
010  
011  
100  
101  
110  
111  
00  
OSR = 256  
OSR = 512  
OSR = 1024  
OSR = 2048  
OSR = 4096  
2.0kΩ  
4-2  
1-0  
RSENSOR  
Sensor Resistance  
2.5kΩ  
3.0kΩ  
3.5kΩ  
4.0kΩ  
4.5kΩ  
5.0kΩ  
10.0kΩ  
PTS  
Pressure/  
Temperature/  
VDD Level Monitoring  
Mode Selection  
Temperature mode  
VDD level monitoring mode  
Pressure mode  
-
01  
10  
11  