Product Specification
108-78140
9.13 Current Cycle Test
① Contacts of signal positions of the connector are turned on with the current
of 3 Ampere, and power positions with the currnt of 4 Ampere. Turning on current
for45 min. and then turning off for 15 min. are defined here as one cycle of
test. The connector is tested with 200 cycles.
② Contacts of signal positions of the connector are turned on with the current
of 3 Ampere and power positions with the current of 8 Ampere shown in fig. 9
at120℃ atmosphere. Thistestcycleisrepeated50 timeswithvibrationapplied
in draft free chamber according to the condition specified in the Table 5. The
connector is vibrated perpendicular to the terminal axis.
Fig. 9
12V
9.14 Over-current Test
While the connector is held horizontally in a draft free chamber,
current is turned on thru one circuit arbitrarily chosen. Current
magnitude and time length for the over-current test are selected
per
the Table 6.
Table 6
Test ①
Test ②
Conduction
Time (s)
Wire Size
Current
Value (A)
Conduction
Time (min.)
Current
Value (A)
0.5
0.85
1.25
30
40
50
80
5
110
170
5
9.15 Dust-Proof Test
Hang the mated connector in the chamber of 900~1200mm each sides. Jet 10
seconds the 1.5Kg of powder specified by JIS Z8901-6 in every 15 minutes.
This test cycle is repeated 8 cycles. Unmated and mate the connector in
every 2 cyles.
9.16 Temperature Rise Test
Conduct the current of 15 Ampere on an optional contact of the connector,
then conduct the current of 6 Ampere on all of the contact. Measurement
is based on per temperature rise magnitude 6.16.
Rev. A8