Product Specification
108-78140
9.11 Vibration Test at High Temperature
The connector is fastened to vibration stand and vibrated on each of the
3mutually perpendicular axis (X, Y, Z) in 125℃ atmosphere. Other
condition of the vibration is set by the Table 5. During the test,
electrical current is turned on as shown in Fig. 8 and intermittent
discontinuity is monitored.
CABLEMOUNT
Fig.8
CABLEMOUNT
Mounting Jig
+5
0
140
+5
0
140
+5
0
140
SHAKER
SHAKER
SHAKER
CABLE MOUNT
+5
0
150
CABLE LENGTH= ꢀꢀꢀꢀmm
Table 5
Acceleration
(m/s2)
Vibration Duration
Vibration Frequency
(Hz)
(h)
50~100 … 98m/s2(10G)constant
98~245
3 hours
100~250※ … Half vibration stroke of 0.2mm constant
~245m/s2(25G)constant
(10~25G)
per direction,
Total of 9 hours
Sweep Time
3min.(Log Sweep)
※
100~176~250Hz
Half vibration stroke constant
(0.2mm)
Acceleration constant
(25G)
9.12 Weather-Proof Test
The connector is left in sunny outdoors for 12 months.
Rev. A8
18 of 41