General Purpose Relays
SCHRACK
Interface Power Relay RT (Continued)
Coil versions, DC-coil
Coil
Rated
voltage
VDC
6
Operate
voltage
VDC
4.2
Release
voltage
VDC
0.6
Coil
Rated coil
power
mW
code
resistance
Ohm
006
012
024
048
060
110
90+10%
400
12
8.4
1.2
360+10%
1440+10%
5520+10%
8570+12%
28800+12%
400
24
16.8
2.4
400
48
33.6
4.8
417
60
42.0
6.0
420
110
77.0
11.0
420
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Coil versions, AC-coil 50Hz
Coil
Rated
Operate
voltage
50 Hz
VAC
Release
voltage
50 Hz
VAC
Coil
Rated coil
power
50 Hz
VA
code
voltage
resistance
VAC
24
Ohm
524
615
730
18.0
3.6
350+10%
8100+15%
32500+15%
0.76
115
230
86.3
17.3
34.5
0.76
0.74
172.5
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Insulation
Dielectric strength coil-contact circuit
open contact circuit
5000 Vrms
1000 Vrms
2500 Vrms
W 10 / 10 mm
W IIIa
adjacent contact circuits
Clearance / creepage coil-contact circuit
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
open contact circuit
PTI 250 V
reinforced
functional
basic
250 V
3
240/400 V
III
adjacent contact circuits
Rated insulation voltage
Terminal assignment
Bottom view on pins
Pollution degree
Rated voltage system
1 CO contact 12 A
Overvoltage category
Other data
1-pole
2-pole
S0163-BC
RoHS - Directive 2002/95/EC
Flammability class according to UL94
Ambient temperature range DC coil
AC coil
compliant as per product date code 0413
V-0
-40...+85°C
-40...+70°C
1 CO contact 16 A
Operate- / release time DC coil
Bounce time DC coil, NO / NC contact
Vibration resistance (function), NO / NC contact
Shock resistance (destruction)
Category of protection
typ 7 / 3 ms
typ 1 / 3 ms
typ 7 / 2 ms
typ 1 / 3 ms
S0163-BE
20 / 5 g, 30 ... 500 Hz
100 g
RTII
Mounting distance
0 mm, dense packing
14 g
2 CO contacts 8 A
Relay weight
Packaging unit
20 / 500 pcs
S0163-BJ
Accessories
For Details see datasheet
Accessories Interface Power Relay RT
Dimensions
Relay Packages
Complete packages consisting of a relay mounted on a socket see Package RT
S0272-BA
2
Datasheet
Rev. HC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
‘Schrack’ section.
Issued 2008/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
only to be used together
with the 'Definitions' at
schrackrelays.com in the
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.