Mechanical Dimensions — Emitter
Lambertian ꢀ LXHLꢀPW03
Notes:
1. The anode side of the device is denoted by a hole in the lead frame. Electrical insulation between the case and the board is
required—slug of device is not electrically neutral. Do not electrically connect either the anode or cathode to the slug.
2. Drawings not to scale.
3. All dimensions are in millimeters.
4. All dimensions without tolerances are for reference only.
Side Emitting ꢀ LXHLꢀDW03
Notes:
1. The anode side of the device is denoted by a hole in the lead frame. Electrical insulation between the case and the board is
required—slug of device is not electrically neutral. Do not electrically connect either the anode or cathode to the slug.
2. Drawings not to scale.
3. All dimensions are in millimeters.
4. All dimensions without tolerances are for reference only.
3
LUXEON V Portable Datasheet DS40 (8/06)