欢迎访问ic37.com |
会员登录 免费注册
发布采购

L8C201NI25 参数 Datasheet PDF下载

L8C201NI25图片预览
型号: L8C201NI25
PDF下载: 下载PDF文件 查看货源
内容描述: 512 / 1K / 2K / 4K ×9位异步FIFO [512/1K/2K/4K x 9-bit Asynchronous FIFO]
分类和应用: 内存集成电路光电二极管先进先出芯片时钟
文件页数/大小: 22 页 / 182 K
品牌: LOGIC [ LOGIC DEVICES INCORPORATED ]
 浏览型号L8C201NI25的Datasheet PDF文件第1页浏览型号L8C201NI25的Datasheet PDF文件第2页浏览型号L8C201NI25的Datasheet PDF文件第4页浏览型号L8C201NI25的Datasheet PDF文件第5页浏览型号L8C201NI25的Datasheet PDF文件第6页浏览型号L8C201NI25的Datasheet PDF文件第7页浏览型号L8C201NI25的Datasheet PDF文件第8页浏览型号L8C201NI25的Datasheet PDF文件第9页  
L8C201/202/203/204  
DEVICES INCORPORATED  
512/1K/2K/4K x 9-bit Asynchronous FIFO  
OPERATING MODES  
4. External logic is needed to generate  
a composite Full Flag (FF) and  
Empty Flag (EF). This requires the  
ORing of all EFs and ORing of all  
FFs (i.e., all must be set to generate  
the correct composite FF or EF).  
Single Device Mode  
A single FIFO may be used when the  
application requirements are for the  
number of words in a single device.  
The FIFOs are in a Single Device  
Configuration when the Expansion In  
(XI) control input is grounded. In this  
mode the Half-Full Flag (HF), which is  
an active-low output, is the active  
function of the combination pin XO/  
HF.  
5. The Retransmit (RT) function and  
Half-Full Flag (HF) are not avail-  
able in the Depth Expansion Mode.  
Bidirectional Mode  
Applications which require data  
buffering between two systems (each  
system capable of read and write  
operations) can be achieved by pairing  
FIFOs. Care must be taken to assure  
that the appropriate flag is monitored  
by each system (i.e., FF is monitored  
on the device when W is used; EF is  
monitored on the device when R is  
used). Both Depth Expansion and  
Width Expansion may be used in this  
mode.  
Width Expansion Mode  
Word width may be increased simply  
by connecting the corresponding input  
control signals of multiple devices.  
Status flags (EF, FF, and HF) can be  
detected from any one device. Any  
word width can be attained by adding  
additional FIFOs. Flag detection is  
accomplished by monitoring the FF,  
EF, and HF signals on either (any)  
device used in the width expansion  
configuration. Do not connect any  
output signals together.  
Depth Expansion (Daisy Chain) Mode  
The FIFOs can easily be adapted to  
applications where the requirements  
are for greater than the number of  
words in a single device. Any depth  
can be attained by adding additional  
FIFOs. The FIFOs operates in the  
Depth Expansion configuration when  
the following conditions are met:  
1. The first device must be designated  
by grounding the First Load (FL)  
control input.  
2. All other devices must have FL in  
the HIGH state.  
3. The Expansion Out (XO) pin of  
each device must be tied to the  
Expansion In (XI) pin of the next  
device with the last device connect-  
OBSOLETE  
ing back to the first.  
FIFO Products  
03/04/99–LDS.8C201/2/3/4-H  
3