 浏览型号C3216X5R0J226MT的Datasheet PDF文件第36页浏览型号C3216X5R0J226MT的Datasheet PDF文件第37页浏览型号C3216X5R0J226MT的Datasheet PDF文件第38页浏览型号C3216X5R0J226MT的Datasheet PDF文件第39页浏览型号C3216X5R0J226MT的Datasheet PDF文件第41页浏览型号C3216X5R0J226MT的Datasheet PDF文件第42页浏览型号C3216X5R0J226MT的Datasheet PDF文件第43页浏览型号C3216X5R0J226MT的Datasheet PDF文件第44页  
LTM4641  
APPLICATIONS INFORMATION—THERMAL CONSIDERATIONS AND  
OUTPUT CURRENT DERATING  
formance of the LTM4641 on DC1543 hardware; a 4-layer  
FR4 PCB measuring 96mm × 87mm × 1.6mm using outer  
and inner copper weights of 2oz and 1oz, respectively. The  
power loss curves are taken at room temperature, and are  
increased with multiplicative factors with ambient tem-  
perature. These approximate factors are listed in Table 3.  
(Compute the factor by interpolation, for intermediate  
temperatures.) The derating curves are plotted with the  
outputcurrentstartingat10Aandtheambienttemperature  
at 40°C. The output voltages are 6V, 3.3V and 1.5V. These  
are chosen to include the lower and higher output voltage  
rangesforcorrelatingthethermalresistance.Thermalmod-  
els are derived from several temperature measurements  
in a controlled temperature chamber along with thermal  
modeling analysis. The junction temperatures are  
monitoredwhileambienttemperatureisincreasedwithand  
without air flow, and with and without a heat sink attached  
with thermally conductive adhesive tape. The BGA heat  
sinks evaluated in Table 7 (and attached to the LTM4641  
with thermally conductive adhesive tape listed in Table 8)  
yield very comparable performance in laminar airflow  
despite being visibly different in construction and form  
factor. The power loss increase with ambient temperature  
change is factored into the derating curves. The junctions  
are maintained at 120°C maximum while lowering output  
currentorpowerwhileincreasingambienttemperature.The  
decreasedoutputcurrentwilldecreasetheinternalmodule  
loss as ambient temperature is increased. The monitored  
junction temperature of 120°C minus the ambient operat-  
ing temperature specifies how much module temperature  
rise can be allowed. As an example in Figure 38, the load  
current is derated to ~8A at ~81°C ambient with no air or  
8A  
condition is ~3.1W. The 3.74W loss is calculated  
OUT  
with the ~3.1W room temperature loss from the 36V to  
IN  
1.5V  
power loss curve at 8A (Figure 20), and the 1.205  
OUT  
multiplying factor at 81°C ambient (interpolating from  
Table 3). If the 81°C ambient temperature is subtracted  
from the 120°C junction temperature, then the difference  
of 39°C divided by 3.74W yields a thermal resistance, θ ,  
JA  
of 10.4°C/W—in good agreement with Table 6. Tables 4,  
5 and 6 provide equivalent thermal resistances for 6V,  
3.3V and 1.5V outputs with and without air flow and heat  
sinking. The derived thermal resistances in Tables 4, 5  
and 6 for the various conditions can be multiplied by the  
calculatedpowerlossasafunctionofambienttemperature  
to derive temperature rise above ambient, thus maximum  
junction temperature. Room temperature power loss can  
be derived from the efficiency curves in the Typical Per-  
formance Characteristics section and adjusted with the  
above ambient temperature multiplicative factors.  
Table 3. Power Loss ꢁultiplicative Factors vs Aꢃbient  
Teꢃperature  
POWER LOSS ꢁULTIPLICATIVE  
AꢁBIENT TEꢁPERATURE  
FACTOR  
1.00  
1.05  
1.10  
1.15  
1.20  
1.25  
1.30  
1.35  
1.40  
Up to 40°C  
50°C  
60°C  
70°C  
80°C  
90°C  
100°C  
110°C  
120°C  
heat sink and the power loss for this 36V to 1.5V  
at  
IN  
OUT  
4641f  
40  
 复制成功!