LT2078/LT2079  
U
W U U  
APPLICATIONS INFORMATION  
The LT2078/LT2079 devices are fully specified with  
V+ = 5V, V= 0V, VCM = 0.1V. This set of operating  
conditions appears to be the most representative for  
battery powered micropower circuits. Offset voltage is  
internally trimmed to a minimum value at these supply  
voltages. When 9V or 3V batteries or ±2.5V dual supplies  
are used, bias and offset current changes will be minimal.  
Offset voltage changes will be just a few microvolts as  
givenbythePSRRandCMRRspecifications.Forexample,  
if PSRR = 114dB (=2µV/V), at 9V the offset voltage change  
will be 8µV. Similarly, VS = ±2.5V, VCM = 0V is equivalent  
to a common mode voltage change of 2.4V or a VOS  
change of 7µV if CMRR = 110dB (3µV/V).  
As an example, consider the instrumentation amplifier  
shown on the front page. When the common mode signal  
is low and the output is high, amplifier A has to sink  
current. When the common mode signal is high and the  
output low, amplifier B has to sink current. The competing  
devices require a 12k pull-down resistor at the output of  
amplifier A and a 15k at the output of B to handle the  
specified signals. (The LT2078 does not need pull-down  
resistors.) When the common mode input is high and the  
outputishighthesepull-downresistorsdraw300µA(150µA  
each), which is excessive for micropower applications.  
The instrumentation amplifier is by no means the only  
application requiring current sinking capability. In seven  
of the nine single supply applications shown in this data  
sheet the op amps have to be able to sink current. In two  
of the applications the first amplifier has to sink only the  
6nA input bias current of thesecond opamp. The compet-  
ing devices, however, cannot even sink 6nA without a  
pull-down resistor  
A full set of specifications is also provided at ±15V supply  
voltages for comparison with other devices and for com-  
pleteness.  
Single Supply Operation  
The LT2078/LT2079 is quite tolerant of power supply  
bypassing. In some applications requiring faster settling  
time the positive supply pin of the LT2078/LT2079 should  
be bypassed with a small capacitor (about 0.1µF). The  
same is true for the negative supply pin when using split  
supplies.  
Since the output of the LT2078/LT2079 cannot go exactly  
to ground, but can only approach ground to within a few  
millivolts, care should be exercised to ensure that the  
output is not saturated. For example, a 1mV input signal  
will cause the amplifier to set up in its linear region in the  
gain 100 configuration shown in Figure 1, but is not  
enough to make the amplifier function properly in the  
voltage follower mode.  
The LT2078/LT2079 are fully specified for single supply  
operation, i.e., when the negative supply is 0V. Input  
common mode range goes below ground and the output  
swings within a few millivolts of ground while sinking  
current. All competing micropower op amps either cannot  
swing to within 600mV of ground (OP-20, OP-220, OP-  
420) or need a pull-down resistor connected to the output  
to swing to ground (OP-90, OP-290, OP-490, HA5141/42/  
44). This difference is critical because in many applica-  
tions these competing devices cannot be operated as  
micropoweropampsandswingtogroundsimultaneously.  
Single supply operation can also create difficulties at the  
input. Thedrivingsignalcanfallbelow0Vinadvertently  
or on a transient basis. If the input is more than a few  
hundred millivolts below ground, two distinct problems  
can occur on previous single supply designs, such as the  
LM124, LM158, OP-20, OP-21, OP-220, OP-221, OP-420  
(1 and 2), OP-90/290/490 (2 only):  
5V  
5V  
R
99R  
OUTPUT  
SATURATION  
100mV  
3.5mV  
1mV  
+
1mV  
+
LT2078/79 • F02a  
LT2078/79 • F02b  
Figure 1a. Gain 100 Amplifier  
Figure 1b. Voltage Follower  
20789fa  