 浏览型号QSW025A0B741-HZ的Datasheet PDF文件第5页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第6页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第7页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第8页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第10页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第11页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第12页浏览型号QSW025A0B741-HZ的Datasheet PDF文件第13页  
Data Sheet  
February 16, 2009  
QSW025A0B Series Power Modules; DC-DC Converters  
36 – 75Vdc Input; 12Vdc Output; 25A Output Current  
temperature to a lower value for extremely high  
reliability.  
Feature Descriptions (continued)  
Thermal Considerations  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  
The power modules operate in a variety of thermal  
environments and sufficient cooling should be provided  
to help ensure reliable operation.  
Thermal considerations include ambient temperature,  
airflow, module power dissipation, and the need for  
increased reliability. A reduction in the operating  
temperature of the module will result in an increase in  
reliability. The thermal data presented here is based on  
physical measurements taken in a wind tunnel.  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat  
transfer via convection. The thermal derating figures  
(15-24) show the maximum output current that can be  
delivered by each module in the respective orientation  
without exceeding the maximum THx temperature  
versus local ambient temperature (TA) for air flows of,  
Natural Convection, 1 m/s (200 ft./min), 2 m/s (400  
ft./min) and 3 m/s (600 ft./min).  
Heat-dissipating components are mounted on the top  
side of the module. Heat is removed by conduction,  
convection and radiation to the surrounding environment.  
Proper cooling can be verified by measuring the thermal  
reference temperature (THx). Peak temperature (THx)  
occurs at the position indicated in Figure 13. For reliable  
operation this temperature should not exceed the listed  
temperature threshold.  
The use of Figures 15 - 24 are shown in the following  
example:  
Example  
What is the minimum airflow necessary for a  
QSW025A0B operating at VI = 48 V, an output current of  
17A, and a maximum ambient temperature of 70 °C in  
transverse orientation.  
Solution:  
Given: Vin= 48V, IO = 17A, TA = 70 °C  
Determine required airflow (V) (Use Figure 15):  
V = 1.5 m/sec. (300LFM) or greater.  
TH1 and TH2 shall not exceed 125°C.  
Figure 13. Location of the thermal reference  
temperature TH.  
TH3 shall not exceed 110°C.  
Figure 14. Location of the thermal reference  
temperature TH3 for Baseplate module.  
The output power of the module should not exceed the  
rated power for the module as listed in the Ordering  
Information table.  
Although the maximum THx temperature of the power  
modules is 110 °C - 125 °C, you can limit this  
LINEAGE POWER  
9