Data Sheet
KW0006-010 Series Power Modules:
September 9, 2008
36 – 75Vdc Input; 3.3 to 5.0Vdc Output; 6 to 10A Output Current
EMC Considerations
Thermal Considerations
The KW006/010 power module is designed to meet
EN55022 Class B Conducted emissions with a simple
filter, as shown in Figure 19. Test results are shown in
Figure 20. Further improvement to the emissions at the
fundamental can be achieved by increasing the value
of C3 and C4. Please contact your Lineage Power
sales representative, if you need further information.
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented in this data sheet is based on
physical measurements taken in a wind tunnel. The test
set-up is shown in Figure 21. Please refer to the
Application Note “Thermal Characterization Process
For Open-Frame Board-Mounted Power Modules” for a
detailed discussion of thermal aspects including
maximum device temperatures.
C3
L1
VIN
+
Vin +
Vout +
C1
C2
KW006A0A4
The thermal reference point, Tref , used in the
specifications, is shown in Figure 22. For reliable
operation this temperature should not exceed 125oC.
VIN
-
Vin -
C4
Vout -
C1 = 4.7uF Ceramic
C2 = 33uF Electrolytic
C3 = 1nF Ceramic
C4 = 1nF Ceramic
L1 = P0354 (1.17mH, 1.2A rated)
Figure 19. EMC Filter.
90
80
70
60
50
40
30
20
EN 55022 Class B Conducted AV (Mains Port)
EN 55022 Class A Conducted AV (Mains Ports)
EN 55022 Class B Conducted AV (Mains Ports)
10
150k
Figure 21. Tref Temperature Measurement
Locations.
1M
10M
30M
Frequency (Hz)
90
80
70
60
50
40
30
20
EN 55022 Class B Conducted AV (Mains Port)
EN 55022 Class A Conducted AV (Mains Ports)
EN 55022 Class B Conducted AV (Mains Ports)
AIRFLOW
10
150k
1M
10M
30M
Frequency (Hz)
Figure 20. EMC Results (top VIN+, bottom VIN-)
Figure 22. Tref Temperature Measurement
Locations.
LINEAGE POWER
10