 浏览型号KW006A0A41-SRZ的Datasheet PDF文件第6页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第7页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第8页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第9页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第11页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第12页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第13页浏览型号KW006A0A41-SRZ的Datasheet PDF文件第14页  
Data Sheet  
KW0006-010 Series Power Modules:  
September 9, 2008  
36 – 75Vdc Input; 3.3 to 5.0Vdc Output; 6 to 10A Output Current  
EMC Considerations  
Thermal Considerations  
The KW006/010 power module is designed to meet  
EN55022 Class B Conducted emissions with a simple  
filter, as shown in Figure 19. Test results are shown in  
Figure 20. Further improvement to the emissions at the  
fundamental can be achieved by increasing the value  
of C3 and C4. Please contact your Lineage Power  
sales representative, if you need further information.  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation.  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented in this data sheet is based on  
physical measurements taken in a wind tunnel. The test  
set-up is shown in Figure 21. Please refer to the  
Application Note “Thermal Characterization Process  
For Open-Frame Board-Mounted Power Modules” for a  
detailed discussion of thermal aspects including  
maximum device temperatures.  
C3  
L1  
VIN  
+
Vin +  
Vout +  
C1  
C2  
KW006A0A4  
The thermal reference point, Tref , used in the  
specifications, is shown in Figure 22. For reliable  
operation this temperature should not exceed 125oC.  
VIN  
-
Vin -  
C4  
Vout -  
C1 = 4.7uF Ceramic  
C2 = 33uF Electrolytic  
C3 = 1nF Ceramic  
C4 = 1nF Ceramic  
L1 = P0354 (1.17mH, 1.2A rated)  
Figure 19. EMC Filter.  
90  
80  
70  
60  
50  
40  
30  
20  
EN 55022 Class B Conducted AV (Mains Port)  
EN 55022 Class A Conducted AV (Mains Ports)  
EN 55022 Class B Conducted AV (Mains Ports)  
10  
150k  
Figure 21. Tref Temperature Measurement  
Locations.  
1M  
10M  
30M  
Frequency (Hz)  
90  
80  
70  
60  
50  
40  
30  
20  
EN 55022 Class B Conducted AV (Mains Port)  
EN 55022 Class A Conducted AV (Mains Ports)  
EN 55022 Class B Conducted AV (Mains Ports)  
AIRFLOW  
10  
150k  
1M  
10M  
30M  
Frequency (Hz)  
Figure 20. EMC Results (top VIN+, bottom VIN-)  