欢迎访问ic37.com |
会员登录 免费注册
发布采购

KBVW006A0B41HZ 参数 Datasheet PDF下载

KBVW006A0B41HZ图片预览
型号: KBVW006A0B41HZ
PDF下载: 下载PDF文件 查看货源
内容描述: [36–75Vdc Input; 12.0Vdc Output; 6A Output Current]
分类和应用:
文件页数/大小: 20 页 / 1370 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号KBVW006A0B41HZ的Datasheet PDF文件第1页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第2页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第3页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第5页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第6页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第7页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第8页浏览型号KBVW006A0B41HZ的Datasheet PDF文件第9页  
Data Sheet  
GE  
KBVW006A0B Series Sixteenth-Brick Power Modules  
36–75Vdc Input; 12.0Vdc Output; 6A Output Current  
Feature Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See  
Feature Descriptions for additional information.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Remote On/Off Signal Interface  
(VIN=VIN, min to VIN, max ; open collector or equivalent,  
Signal referenced to VIN- terminal)  
Negative Logic: device code suffix “1”  
Logic Low = module On, Logic High = module Off  
Positive Logic: No device code suffix required  
Logic Low = module Off, Logic High = module On  
Logic Low - Remote On/Off Current  
All  
All  
All  
All  
Ion/off  
Von/off  
Von/off  
Ion/off  
0.15  
0.6  
15  
mA  
Vdc  
Vdc  
μA  
-0.7  
2.4  
Logic Low - On/Off Voltage  
Logic High Voltage – (Typ = Open Collector)  
Logic High maximum leakage current  
Turn-On Delay1 and Rise Times  
25  
(IO=IO, max , VIN=VIN, nom, TA = 25oC)  
Case 1: Input power is applied for at least 1 second  
and then the On/Off input is set from OFF to ON (Tdelay = from  
instant at which On/Off signal is ON until VO = 10% of VO, set).  
All  
All  
Tdelay  
20  
msec  
msec  
Case 2: On/Off input is set to Logic Low (Module  
ON) and then input power is applied (Tdelay from  
Tdelay  
150  
instant at which VIN = VIN, min until Vo=10% of VO,set  
Output voltage Rise time (time for Vo to rise from 10%  
of Vo,set to 90% of Vo, set  
)
All  
All  
Trise  
5
12  
3
msec  
)
Output voltage overshoot – Startup  
IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 oC  
Prebiased Output Load Performance:  
% VO, set  
All  
Monotonic  
Output Start up characteristic  
Back Bias current drawn from output (Module Enabled)  
Back Bias current drawn from output (Module Disabled)  
All  
All  
All  
All  
All  
All  
All  
-50  
-50  
mAdc  
mAdc  
% VO, set  
% VO, set  
Vdc  
Remote Sense Range  
VSENSE  
10  
110  
16.5  
Output Voltage Adjustment Range  
Output Overvoltage Protection  
Overtemperature Protection – Hiccup Auto Restart  
Input Undervoltage Lockout  
Turn-on Threshold  
80  
13.8  
VO, limit  
Tref  
135  
OC  
VUVLO  
32  
30  
2
34.5  
Vdc  
Vdc  
Vdc  
27.5  
1
Turn-off Threshold  
Hysteresis  
1.  
The module has an adaptable extended Turn-On Delay interval, Tdelay, of 25mS. The extended Tdelay will occur when the module restarts following either: 1)  
the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back to normal; or 2)  
toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, Tdelay, will occur whenever a  
module restarts with input voltage removed from the module for the preceding 1 second.  
2.  
The module requires a minimum of 220 μF external output capacitor to prevent shutdown during no load to full load transients and to avoid exceeding the  
OVP maximum limits during startup into open loop fault conditions.  
July 9, 2013  
©2012 General Electric Company. All rights reserved.  
Page 4  
 复制成功!