Data Sheet
GE
KBVW006A0B Series Sixteenth-Brick Power Modules
36–75Vdc Input; 12.0Vdc Output; 6A Output Current
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current
All
All
All
All
Ion/off
Von/off
Von/off
Ion/off
0.15
0.6
15
mA
Vdc
Vdc
μA
-0.7
2.4
Logic Low - On/Off Voltage
Logic High Voltage – (Typ = Open Collector)
Logic High maximum leakage current
Turn-On Delay1 and Rise Times
25
(IO=IO, max , VIN=VIN, nom, TA = 25oC)
Case 1: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (Tdelay = from
instant at which On/Off signal is ON until VO = 10% of VO, set).
All
All
Tdelay
—
20
—
—
msec
msec
Case 2: On/Off input is set to Logic Low (Module
ON) and then input power is applied (Tdelay from
Tdelay
—
—
150
instant at which VIN = VIN, min until Vo=10% of VO,set
Output voltage Rise time (time for Vo to rise from 10%
of Vo,set to 90% of Vo, set
)
All
All
Trise
5
12
3
msec
)
Output voltage overshoot – Startup
IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 oC
Prebiased Output Load Performance:
—
% VO, set
All
Monotonic
Output Start up characteristic
Back Bias current drawn from output (Module Enabled)
Back Bias current drawn from output (Module Disabled)
All
All
All
All
All
All
All
-50
-50
mAdc
mAdc
% VO, set
% VO, set
Vdc
Remote Sense Range
VSENSE
10
110
16.5
Output Voltage Adjustment Range
Output Overvoltage Protection
Overtemperature Protection – Hiccup Auto Restart
Input Undervoltage Lockout
Turn-on Threshold
80
13.8
VO, limit
Tref
135
OC
VUVLO
32
30
2
34.5
Vdc
Vdc
Vdc
27.5
1
Turn-off Threshold
Hysteresis
1.
The module has an adaptable extended Turn-On Delay interval, Tdelay, of 25mS. The extended Tdelay will occur when the module restarts following either: 1)
the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back to normal; or 2)
toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, Tdelay, will occur whenever a
module restarts with input voltage removed from the module for the preceding 1 second.
2.
The module requires a minimum of 220 μF external output capacitor to prevent shutdown during no load to full load transients and to avoid exceeding the
OVP maximum limits during startup into open loop fault conditions.
July 9, 2013
©2012 General Electric Company. All rights reserved.
Page 4