欢迎访问ic37.com |
会员登录 免费注册
发布采购

JHC350R4Z 参数 Datasheet PDF下载

JHC350R4Z图片预览
型号: JHC350R4Z
PDF下载: 下载PDF文件 查看货源
内容描述: 18 - 36VDC或36 - 75VDC输入; 28VDC输出; 350W [18 - 36Vdc or 36 - 75Vdc Input; 28Vdc Output; 350W]
分类和应用:
文件页数/大小: 16 页 / 579 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号JHC350R4Z的Datasheet PDF文件第4页浏览型号JHC350R4Z的Datasheet PDF文件第5页浏览型号JHC350R4Z的Datasheet PDF文件第6页浏览型号JHC350R4Z的Datasheet PDF文件第7页浏览型号JHC350R4Z的Datasheet PDF文件第9页浏览型号JHC350R4Z的Datasheet PDF文件第10页浏览型号JHC350R4Z的Datasheet PDF文件第11页浏览型号JHC350R4Z的Datasheet PDF文件第12页  
Data Sheet  
JHC/JHW350 Power Module; dc-dc Converter  
March 26, 2008  
18 – 36Vdc or 36 – 75Vdc Input; 28Vdc Output; 350W  
Test Configurations  
Design Considerations  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance source. Highly inductive source  
impedance can affect the stability of the power  
module. For the test configuration in Figure 13, a  
200μF electrolytic capacitor (ESR<0.7Ω at 100kHz),  
mounted close to the power module helps ensure the  
stability of the unit. Consult the factory for further  
application guidelines.  
Output Capacitance  
Note: Measure input reflected-ripple current with a simulated  
source inductance (LTEST) of 12 µH. Capacitor CS offsets  
possible battery impedance. Measure current as shown  
above.  
Figure 13. Input Reflected Ripple Current Test  
Setup.  
Output capacitance and load impedance interact with  
the power module’s output voltage regulation control  
system and may produce an ’unstable’ output  
condition for the required values of capacitance and  
E.S.R.. Minimum and maximum values of output  
capacitance and of the capacitor’s associated E.S.R.  
may be dictated, depending on the module’s control  
system. This series power module requires minimum  
of 330µF output capacitance placed near output pins  
to ensure stable operation in full range of load/line  
conditions.  
The process of determining the acceptable values of  
capacitance and E.S.R. is complex and is load-  
dependant. Lineage Power provides Web-based tools  
to assist the power module end-user in appraising  
and adjusting the effect of various load conditions and  
output capacitances on specific power modules for  
various load conditions.  
Note: Use a 1.0 µF ceramic capacitor and a 1000µF  
aluminum or tantalum capacitor. Scope measurement should  
be made  
using a BNC socket. Position the load between  
51 mm and 76 mm (2 in. and 3 in.) from the module.  
Figure 14. Output Ripple and Noise Test Setup.  
Note: All measurements are taken at the module terminals.  
When socketing, place Kelvin connections at module  
terminals to avoid measurement errors due to socket contact  
resistance.  
Figure 15. Output Voltage and Efficiency Test  
Setup.  
LINEAGE POWER.  
8