JBW050F Power Modules: dc-dc Converter;  
36 to 75 Vdc Input, 3.3 Vdc Output; 33 W  
Data Sheet  
September 20, 2004  
Use Figure 20 to determine air velocity for the 1/2 inch heat sink.  
The minimum airflow necessary for the JBW050F  
module is 1.27 m/s (250 ft./min.).  
Custom Heat Sinks  
A more detailed model can be used to determine the required thermal resistance of a heat sink to provide neces-  
sary cooling. The total module resistance can be separated into a resistance from case-to-sink (θcs) and sink-to-  
ambient (θsa) shown below (Figure 21).  
TC  
TS  
TA  
PD  
θcs  
θsa  
8-1304  
Figure 21. Resistance from Case-to-Sink and  
Sink-to-Ambient  
For a managed interface using thermal grease or foils, a value of θcs = 0.1 °C/W to 0.3 °C/W is typical. The solution  
for heat sink resistance is:  
(TC TA)  
------------------------  
PD  
θsa =  
θcs  
This equation assumes that all dissipated power must be shed by the heat sink. Depending on the user-defined  
application environment, a more accurate model, including heat transfer from the sides and bottom of the module,  
can be used. This equation provides a conservative estimate for such instances.  
Solder, Cleaning, and Drying Considerations  
Post solder cleaning is usually the final circuit-board assembly process prior to electrical testing. The result of inad-  
equate circuit-board cleaning and drying can affect both the reliability of a power module and the testability of the  
finished circuit-board assembly. For guidance on appropriate soldering, cleaning, and drying procedures, refer to  
the Board-Mounted Power Modules Soldering and Cleaning Application Note (AP01-056EPS).  
EMC Considerations  
For assistance with designing for EMC compliance, please refer to the FLTR100V10 data sheet  
(FDS01-043EPS).  
Layout Considerations  
Copper paths must not be routed beneath the power module mounting inserts. For additional layout guidelines,  
refer to the FLTR100V10 data sheet  
(FDS01-043EPS).  
Tyco Electronics Power Systems  