JBW050F Power Modules: dc-dc Converter;
36 to 75 Vdc Input, 3.3 Vdc Output; 33 W
Data Sheet
September 20, 2004
Electrical Specifications
(continued)
Table 3. Isolation Specifications
Parameter
Isolation Capacitance
Isolation Resistance
Min
—
10
Typ
2500
—
Max
—
—
Unit
pF
MΩ
General Specifications
Parameter
Calculated MTBF (I
O
= 80% of I
O, max
; T
C
= 40 °C)
Weight
—
Min
Typ
3,210,000
—
100 (3.5)
Max
Unit
hr.
g (oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Remote On/Off Signal Interface
(V
I
= 0 V to 75 V; open collector or equivalent compatible;
signal referenced to V
I
(–) terminal; see Figure 11 and
Feature Descriptions.):
Preferred Logic:
Logic Low—Module On
Logic High—Module Off
Optional Logic:
Logic Low—Module Off
Logic High—Module On Logic Low:
At I
on/off
= 1.0 mA
At V
on/off
= 0.0 V
Logic High:
At I
on/off
= 0.0 µA
Leakage Current
Turn-on Time (See Figure 7.)
(I
O
= 80% of I
O, max
; V
O
within ±1% of steady state)
Output Voltage Adjustment (See Feature Descriptions.):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
Output Overvoltage Protection
Overtemperature Protection (shutdown)
* These are manufacturing test limits. In some situations, results may differ.
Symbol
Min
Typ
Max
Unit
V
on/off
I
on/off
V
on/off
I
on/off
—
0
—
—
—
—
—
—
—
—
20
1.2
1.0
15
50
35
V
mA
V
µA
ms
—
—
V
O, clamp
T
C
—
60
3.8*
—
—
—
—
105
0.5
110
5.3*
—
V
%V
O, nom
V
°C
4
Tyco Electronics Power Systems