欢迎访问ic37.com |
会员登录 免费注册
发布采购

JBW050F1 参数 Datasheet PDF下载

JBW050F1图片预览
型号: JBW050F1
PDF下载: 下载PDF文件 查看货源
内容描述: 36至75 VDC输入, 3.3 Vdc输出; 33 W¯¯ [36 to 75 Vdc Input, 3.3 Vdc Output; 33 W]
分类和应用:
文件页数/大小: 16 页 / 334 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号JBW050F1的Datasheet PDF文件第1页浏览型号JBW050F1的Datasheet PDF文件第3页浏览型号JBW050F1的Datasheet PDF文件第4页浏览型号JBW050F1的Datasheet PDF文件第5页浏览型号JBW050F1的Datasheet PDF文件第6页浏览型号JBW050F1的Datasheet PDF文件第7页浏览型号JBW050F1的Datasheet PDF文件第8页浏览型号JBW050F1的Datasheet PDF文件第9页  
JBW050F Power Modules: dc-dc Converter;
36 to 75 Vdc Input, 3.3 Vdc Output; 33 W
Data Sheet
September 20, 2004
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Input Voltage:
Continuous:
Transient (100 ms)
I/O Isolation Voltage
Operating Case Temperature
(See Thermal Considerations section.)
Storage Temperature
Symbol
V
I
V
I, trans
T
C
T
stg
Min
–40
–55
Max
75
100
1500
100
125
Unit
Vdc
V
Vdc
°C
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Parameter
Operating Input Voltage
Maximum Input Current
(V
I
= 0 V to 75 V; I
O
= I
O, max
):
JBW050F (See Figure 1.)
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
(5 Hz to 20 MHz, 12 µH source impedance;
see Figure 8.)
Input Ripple Rejection (120 Hz)
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a fast-acting fuse with a maximum rating of 10 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
Symbol
V
I
Min
36
Typ
48
Max
75
Unit
Vdc
I
I, max
i
2
t
I
I
5
1.2
1.0
A
A
2
s
mAp-p
60
dB
2
Tyco Electronics Power Systems