JBW030-Series Power Module: dc-dc Converters  
36-75 Vdc Input; 3.3 Vdc and 5 Vdc Outputs; 30 W  
Data Sheet  
March 27, 2008  
Thermal Considerations  
The JBW030-Series Power Modules are designed to operate in a variety of thermal environments. As with any  
electronic component, sufficient cooling must be provided to help ensure reliable operation. Heat-dissipating com-  
ponents inside the module are thermally coupled to the case to enable heat removal by conduction, convection,  
and radiation to the surrounding environment.  
The thermal data presented is based on measurements taken in a wind tunnel. The test setup shown in Figure 18  
was used to collect data for Figure 21.  
The graphs in Figures 19 and 20 provide general guidelines for use. Actual performance can vary depending on  
the particular application environment. The maximum case temperature of 100 °C must not be exceeded.  
12.7 (0.50)  
WIND TUNNEL  
WALL  
MEASURE CASE  
TEMPERATURE (TC) AT  
CENTER OF UNIT  
AIR-  
FLOW  
CONNECTORS TO  
LOADS, POWER  
SUPPLIES, AND  
DATALOGGER,  
6.35 (0.25) TALL  
203.2  
(8.00)  
AIRFLOW  
76.2  
(3.00)  
101.6  
(4.00)  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
MEASURED  
BELOW THE  
MODULE  
203.2 (8.00)  
19.1 (0.75)  
8-1046(C)  
Note: Dimensions are in millimeters and (inches).  
Figure 18. Thermal Test Setup  
Basic Thermal Performance  
The JBW030-Series Power Modules are constructed with a specially designed, heat spreading enclosure. As a  
result, full-load operation in natural convection at 50 °C can be achieved without the use of an external heat sink.  
Higher ambient temperatures can be sustained by increasing the airflow or by adding a heat sink. As stated, this  
data is based on a maximum case temperature of 100 °C and measured in the test configuration shown in  
Figure 18.  
Lineage Power  
11