Data Sheet  
EUE Series DC-DC Power Modules:  
March 19, 2009  
42-55/42-58Vdc Input; 12Vdc Output; 200/120W  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Input Voltage  
Continuous  
Device  
Symbol  
Min  
Max  
Unit  
EUE200  
EUE120  
All  
VIN  
VIN  
-0.3  
-0.3  
-0.3  
-40  
55  
58  
75  
85  
Vdc  
Vdc  
Vdc  
°C  
Non-Operating Condition  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
All  
TA  
All  
All  
Tstg  
-40  
100  
°C  
I/O Isolation (100% factory Hi-Pot tested)  
2250  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
Symbol  
Min  
42  
Typ  
48  
Max  
55  
Unit  
Operating Input Voltage  
EUE200  
EUE120  
VIN  
VIN  
Vdc  
Vdc  
42  
48  
58  
Maximum Input Current  
Adc  
Adc  
(EUE200:VIN=0 to 55V , Po = 200W, max  
(EUE120:VIN=0 to 58V , Po = 120W, max  
)
)
EUE200  
EUE120  
IIN,max  
IIN,max  
5.6  
3.5  
I2t  
1
A2s  
mAp-p  
dB  
Inrush Transient  
All  
All  
All  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0  
to 55V, Po = 200W, max ;See Figure 17)  
5
Input Ripple Rejection (120Hz)  
12.3  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being  
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to  
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-  
acting fuse with a maximum rating of 10A (see Safety Considerations section). Based on the information provided in  
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be  
used. Refer to the fuse manufacturer’s data sheet for further information.  
LINEAGE POWER  