Data Sheet  
EUE Series DC-DC Power Modules:  
March 19, 2009  
42-55/42-58Vdc Input; 12Vdc Output; 200/120W  
Test Configurations  
Safety Considerations  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and  
separation requirements of the end-use safety agency  
standard, i.e., UL60950-1, CSA C22.2 No. 60950-1-  
03, EN60950-1 and VDE 0805:2001-12.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements.  
Note: Measure input reflected-ripple current with a simulated  
source inductance (LTEST) of 12 µH. Capacitor CS offsets  
possible battery impedance. Measure current as shown  
above.  
For all input voltages, other than DC MAINS, where  
the input voltage is less than 60V dc, if the input  
meets all of the requirements for SELV, then:  
Figure 17. Input Reflected Ripple Current Test  
Setup.  
The output may be considered SELV. Output  
voltages will remain within SELV limits even with  
internally-generated non-SELV voltages. Single  
component failure and fault tests were performed  
in the power converters.  
One pole of the input and one pole of the output  
are to be grounded, or both circuits are to be kept  
floating, to maintain the output voltage to ground  
voltage within ELV or SELV limits.  
If the input meets extra-low voltage (ELV)  
requirements, then the converter’s output is  
considered ELV  
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum  
or tantalum capacitor. Scope measurement should be made  
using a BNC socket. Position the load between 51 mm and  
76 mm (2 in. and 3 in.) from the module.  
Figure 18. Output Ripple and Noise Test Setup.  
CONTACT AND  
DISTRIBUTION LOSSES  
All flammable materials used in the manufacturing of  
these modules are rated 94V-0, or tested to the  
UL60950 A.2 for reduced thickness.  
The input to these units is to be provided with a  
maximum 10A fast-acting fuse in the unearthed lead.  
V
SUP
CONTACT  
RESISTANCE  
Note: All measurements are taken at the module terminals.  
When socketing, place Kelvin connections at module  
terminals to avoid measurement errors due to socket contact  
resistance.  
Figure 19. Output Voltage and Efficiency Test  
Setup.  
VO. IO  
Efficiency  
=
x
100 %  
η
VIN. IIN  
LINEAGE POWER  
9