 浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第5页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第6页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第7页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第8页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第10页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第11页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第12页浏览型号ESTW010A0A41-HZ的Datasheet PDF文件第13页  
Data Sheet  
ESTW010A0A Series Eighth-Brick Power Modules  
November 29, 2011  
3675Vdc Input; 5.0Vdc Output; 10A Output Current  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation.  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel.  
AMBIENT TEMEPERATURE, TA (oC)  
The thermal reference points, Tref1 and Tref2, used in  
the specifications for open frame modules are shown  
in Figure 13. For reliable operation these  
temperatures should not exceed 110oC and 125 oC  
respectively.  
Figure 15. Output Current Derating for the Open  
Frame Module; Airflow in the Transverse Direction  
from Vout(+) to Vout(-); Vin =48V.  
AIRFLOW  
Figure 13. Tref 1 & Tref2 Temperature Measurement  
Locations for Open Frame Module.  
AMBIENT TEMEPERATURE, TA (oC)  
Figure 16. Output Current Derating for the Module  
with Heatplate; Airflow in the Transverse Direction  
from Vout(+) to Vout(-); Vin =48V.  
The thermal reference point, Tref, used in the  
specifications for modules with heatplate is shown in  
Figure 14. For reliable operation this temperature  
should not exceed 110oC.  
Figure 14. Tref Temperature Measurement  
Location for Module with Heatplate.  
AMBIENT TEMEPERATURE, TA (oC)  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat  
transfer via convection. Derating curves showing the  
maximum output current that can be delivered by  
each module versus local ambient temperature (TA)  
for natural convection and up to 1m/s (200 ft./min)  
forced airflow are shown in Figure 15.  
Figure 17. Output Current Derating for the Open  
Frame Module with Heatplate and 0.25” Heatsink;  
Airflow in the Transverse Direction from Vout(+) to  
Vout(-); Vin =48V.  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  