Data Sheet  
GE  
ESTW015A0A Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 5.0Vdc, 15A, 75W Output  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings  
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations  
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
Continuous  
All  
All  
All  
-H  
VIN  
VIN,trans  
TA  
-0.3  
-0.3  
-40  
-40  
80  
100  
85  
Vdc  
Vdc  
°C  
Transient, operational (100 ms)  
Operating Ambient Temperature  
Maximum Heat Plate Operating Temperature  
(see Thermal Considerations section)  
Altitude*  
TC  
105  
°C  
All  
All  
All  
4000  
125  
m
°C  
Storage Temperature  
Tstg  
-55  
I/O Isolation voltage (100% factory Hi-Pot tested)  
2250  
Vdc  
* For higher altitude applications, contact your GE Sales Representative for alternative conditions of use.  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
All  
VIN  
36  
48  
75  
Vdc  
Maximum Input Current  
All  
IIN  
2.7  
Adc  
(VIN= VIN, min to VIN, max, VO= VO, set, IO=IO, max  
Input No Load Current  
)
All  
All  
IIN,No load  
70  
5
mA  
(VIN = 48V, IO = 0, module enabled)  
Input Stand-by Current  
IIN,stand-by  
I2t  
8
mA  
A2s  
(VIN = 48V, module disabled)  
Inrush Transient  
All  
All  
All  
0.5  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ; See  
Test configuration section)  
30  
50  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part  
of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve  
maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a  
maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy  
and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet  
for further information.  
March 28, 2013  
©2012 General Electric Company. All rights reserved.  