Data Sheet
EQD075 Series Single Output: Eighth Brick Power Modules:
18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W
March 25, 2008
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
A
A
A
A
VIN
VIN, trans
TA
-0.3
-0.3
-40
60
75
85
Vdc
Vdc
°C
Transient (100 ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation (100% factory Hi-Pot tested)
Input - Output
Tstg
-55
125
°C
1500
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
18
24/48
60
Operating Input Voltage
A
VIN
Vdc
Maximum Input Current
Adc
mA
(VIN=0 to VIN, max , Vo = Vo,set, IO=IO, max
)
A
A
IIN,max
6
Input Stand-by Current
Module on / off disabled (VIN = VIN, nom, Vo = 0 V)
Input No Load Current
IIN, Stby
25
mA
A2s
Module on / off enabled (VIN = VIN, nom, Io = 0 A)
A
A
IIN, NL
I2t
110
1
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance;
Ta 25oC, Cin = 33μF)
A
A
30
mAp-p
dB
Input Ripple Rejection (100 - 120Hz)
50
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a very
fast acting surface mount fuse with a maximum rating of 6.3 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER