Data Sheet  
EQD075 Series Single Output: Eighth Brick Power Modules:  
18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W  
March 25, 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
Continuous  
A
A
A
A
VIN  
VIN, trans  
TA  
-0.3  
-0.3  
-40  
60  
75  
85  
Vdc  
Vdc  
°C  
Transient (100 ms)  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
I/O Isolation (100% factory Hi-Pot tested)  
Input - Output  
Tstg  
-55  
125  
°C  
1500  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
18  
24/48  
60  
Operating Input Voltage  
A
VIN  
Vdc  
Maximum Input Current  
Adc  
mA  
(VIN=0 to VIN, max , Vo = Vo,set, IO=IO, max  
)
A
A
IIN,max  
6
Input Stand-by Current  
Module on / off disabled (VIN = VIN, nom, Vo = 0 V)  
Input No Load Current  
IIN, Stby  
25  
mA  
A2s  
Module on / off enabled (VIN = VIN, nom, Io = 0 A)  
A
A
IIN, NL  
I2t  
110  
1
Inrush Transient  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance;  
Ta 25oC, Cin = 33μF)  
A
A
30  
mAp-p  
dB  
Input Ripple Rejection (100 - 120Hz)  
50  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being  
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to  
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a very  
fast acting surface mount fuse with a maximum rating of 6.3 A (see Safety Considerations section). Based on the  
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a  
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.  
LINEAGE POWER  
2
 复制成功!