Data Sheet  
EQD075 Series Single Output: Eighth Brick Power Modules:  
18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W  
March 25, 2008  
Test Configurations  
Design Considerations  
Input Filtering  
CURRENT PROBE  
TO OSCILLOSCOPE  
The power module should be connected to a low ac-  
impedance source. Highly inductive source  
L
TEST  
V
(+)  
IN  
impedance can affect the stability of the power  
module. For the test configuration in Figure 17, a  
220µF electrolytic capacitor (ESR<0.1at 100 kHz),  
mounted close to the power module helps ensure the  
stability of the unit. Consult your sales representative  
for further applications guidelines.  
12μH  
BATTERY  
C
IN  
C
220μF  
Electrolytic  
S
μF  
33  
Ceramic  
Ω
E.S.R.<0.1  
@ 20°C 100kHz  
COM  
Safety Considerations  
NOTE: Measure input reflected ripple current with a simulated  
source inductance (L TEST ) of 12μH. Capacitor C S offsets  
possible battery impedance. Measure current as shown  
above.  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and  
separation requirements of the end-use safety agency  
standard, i.e., UL60950-1, CSA C22.2 No. 60950-1-  
03, EN60950-1 and VDE 0805:2001-12.  
Figure 17. Input Reflected Ripple Current Test  
Setup.  
These converters have been evaluated to the spacing  
requirements for Basic insulation, per the above  
safety standards; and 1500 Vdc is applied from Vin to  
Vout to 100% of outgoing production.  
COPPER STRIP  
VO(+)  
COM  
RESISTIVE  
LOAD  
For end products connected to –48V dc nominal DC  
MAINS (i.e. central office dc battery plant), no further  
fault testing is required. For all input voltages, other  
than DC MAINS, where the input voltage is less than  
60V dc, if the input meets all of the requirements for  
SELV, then:  
1uF  
.
10uF  
SCOPE  
GROUND PLANE  
NOTE: All voltage measurements to be taken at the module  
terminals, as shown above. If sockets are used then  
Kelvin connections are required at the module terminals  
to avoid measurement errors due to socket contact  
resistance.  
ƒ The output may be considered SELV. Output  
voltages will remain within SELV limits even with  
internally-generated non-SELV voltages. Single  
component failure and fault tests were performed  
in the power converters.  
Figure 18. Output Ripple and Noise Test Setup.  
ƒ One pole of the input and one pole of the output  
are to be grounded, or both circuits are to be kept  
floating, to maintain the output voltage to ground  
voltage within ELV or SELV limits.  
Rdistribution Rcontact  
Rcontact Rdistribution  
VIN(+)  
VO  
The power module has ELV (extra-low voltage)  
outputs when all inputs are ELV.  
RLOAD  
VO  
VIN  
Rdistribution Rcontact  
Rcontact Rdistribution  
All flammable materials used in the manufacturing of  
these modules are rated 94V-0, or tested to the  
UL60950 A.2 for reduced thickness.  
COM  
COM  
NOTE: All voltage measurements to be taken at the module  
terminals, as shown above. If sockets are used then  
Kelvin connections are required at the module terminals  
to avoid measurement errors due to socket contact  
resistance.  
The input to these units is to be provided with a  
maximum 6.3 A very fast-acting surface mount fuse in  
the unearthed lead.  
Figure 19. Output Voltage and Efficiency Test  
Setup.  
VO. IO  
Efficiency  
=
x
100 %  
η
VIN. IIN  
9
 复制成功!