欢迎访问ic37.com |
会员登录 免费注册
发布采购

EHHD006A0B41-SZ 参数 Datasheet PDF下载

EHHD006A0B41-SZ图片预览
型号: EHHD006A0B41-SZ
PDF下载: 下载PDF文件 查看货源
内容描述: EHHD006A0B系列(八分之一砖)的DC -DC转换器电源模块 [EHHD006A0B Series (Eighth-Brick) DC-DC Converter Power Modules]
分类和应用: 转换器电源电路
文件页数/大小: 19 页 / 1426 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第3页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第4页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第5页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第6页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第8页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第9页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第10页浏览型号EHHD006A0B41-SZ的Datasheet PDF文件第11页  
Data Sheet
August 29, 2011
Feature Descriptions
Remote On/Off
EHHD006A0B Series Eighth-Brick Power Modules
18 - 75Vdc Input; 12V/6A
dc
Output
The amount of power delivered by the module is
defined as the voltage at the output terminals
multiplied by the output current. When using remote
sense and trim, the output voltage of the module can
be increased, which at the same output current would
increase the power output of the module. Care should
be taken to ensure that the maximum output power of
the module remains at or below the maximum rated
power (maximum rated power = Vo,set x Io,max).
SENSE(+)
SENSE(–)
V
I
(+)
V
O
(+)
V
O
(–)
CONT
ACT AND
DISTRIBUTION LOSSE
Two remote On/Off options are available. Positive
logic turns the module on during a logic high voltage
on the On/Off pin and off during a logic low. Negative
logic remote On/Off, device code suffix “1”, turns the
module off during a logic high and on during a logic
low.
Vin+
Vout+
I
on/off
ON/OFF
SUPPL
Y
I
I
I
O
LOAD
TRIM
V
on/off
V
I
(-)
CONT
ACT
RESIST
ANCE
Vin-
Vout-
Figure 11. Circuit Configuration for Remote
Sense .
Input Undervoltage Lockout
Figure 10. Remote On/Off Implementation.
To turn the power module on and off, the user must
supply a switch (open collector or equivalent) to
control the voltage (V
on/off
) between the On/Off
terminal and the V
IN
(-) terminal (see Figure 10). Logic
low is 0V
V
on/off
1.2V. The maximum I
on/off
during a
logic low is 1mA and the switch should maintain a
logic low level while sinking this current.
During a logic high, the typical maximum V
on/off
generated by the module is 5.6V and the maximum
allowable leakage current at V
on/off
= 5.6V is 25μA.
If not using the remote On/Off feature:
For positive logic, leave the On/Off pin open.
For negative logic, short the On/Off pin to V
IN
(-).
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module
will only begin to operate once the input voltage is
raised above the undervoltage lockout turn-on
threshold, V
UV/ON
.
Once operating, the module will continue to operate
until the input voltage is taken below the undervoltage
turn-off threshold, V
UV/OFF
.
Overtemperature Protection
To provide protection under certain fault conditions,
the unit is equipped with a thermal shutdown circuit.
The unit will shutdown if the thermal reference point,
O
O
Tref, exceeds 135 C (Figure 13, typical) or 120 C
(Figure 14, typical), but the thermal shutdown is not
intended as a guarantee that the unit will survive
temperatures beyond its rating. The module will
automatically restart upon cool-down to a safe
temperature.
Remote Sense
Remote sense minimizes the effects of distribution
losses by regulating the voltage at the remote-sense
connections (See Figure 11). The voltage between
the remote-sense pins and the output terminals must
not exceed the output voltage sense range given in
the Feature Specifications table:
[V
O
(+) – V
O
(–)] – [SENSE(+) – SENSE(–)]
0.5 V
Although the output voltage can be increased by both
the remote sense and by the trim, the maximum
increase for the output voltage is not the sum of both.
The maximum increase is the larger of either the
remote sense or the trim.
Output Overvoltage Protection
The output overvoltage protection scheme of the
modules has an independent overvoltage loop to
prevent single point of failure. This protection feature
latches in the event of overvoltage across the output.
Cycling the On/Off pin or input voltage resets the
latching protection feature. If the auto-restart option
(4) is ordered, the module will automatically restart
upon an internally programmed time elapsing.
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current
limiting continuously. At the point of current-limit
inception, the unit enters hiccup mode. If the unit is
not configured with auto–restart, it will latch off
following the overcurrent condition. The module can
be restarted by cycling the DC input power for at least
LINEAGE
POWER
7