 浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第5页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第6页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第7页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第8页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第10页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第11页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第12页浏览型号CAR2512TEBX5Z01A的Datasheet PDF文件第13页  
Preliminary Data Sheet  
GE  
CAR2512TE Front-End  
Input: 90VAC to 264VAC; Output: 12 VDC @ 2500W; 3.3/5VDC standby @ 15W  
PMBusTM Commands  
SMBAlert#: The µC driven SMBAlert# signal informs the  
‘master/host’ controller that either a STATE or ALARM change  
has occurred. Normally this signal is HI. The signal will change  
to its LO level if the power supply has changed states and the  
signal will be latched LO until the power supply receives a  
‘clear’ instruction as outlined below. If the alarm state is still  
present after the ‘clear_faults’ command has been received,  
then the signal will revert back into its LO state again and will  
latch until a subsequent ‘clear_faults’ signal is received from  
the host controller.  
Standard instruction: Up to two bytes of data may follow an  
instruction depending on the required data content. Analog  
data is always transmitted as LSB followed by MSB. PEC is  
optional and includes the address and data fields.  
1
S
8
1
A
8
1
A
Slave address  
Wr  
Command Code  
8
1
A
8
1
A
8
PEC  
1
A
1
P
The signal will be triggered for any state change, including the  
following conditions;  
Low data byte  
High data byte  
Master to Slave  
Slave to Master  
VIN under or over voltage  
Vout under or over voltage  
IOUT over current  
Over Temperature warning or fault  
Fan Failure  
Communication error  
PEC error  
Invalid command  
SMBUS annotations; S – Start , Wr – Write, Sr – re-Start, Rd –  
Read,  
A – Acknowledge, NA – not-acknowledged, P – Stop  
Standard READ: Up to two bytes of data may follow a READ  
request depending on the required data content. Analog data  
is always transmitted as LSB followed by MSB. PEC is  
mandatory and includes the address and data fields. PEC is  
optional and includes the address and data fields.  
Detected internal faults  
The power supply will clear the SMBusAlert# signal (release the  
signal to its HI state) upon the following events:  
1
S
7
1
Wr  
1
A
8
1
A
Slave address  
Command Code  
Receiving a CLEAR_FAULTS command  
The main output recycled (turned OFF and then ON) via  
the REMOTE ON/OFF signal pin  
1
7
1
1
A
8
LSB  
1
A
Sr Slave Address  
Rd  
The main output recycled (turned OFF and then ON) by the  
OPERATION command  
8
MSB  
1
A
8
PEC  
1
1
P
No-ack  
Block communications: When writing or reading more than  
two bytes of data at a time, BLOCK instructions for WRITE and  
READ commands must be used instead of the Standard  
Instructions  
Read back delay: The power supply issues the SMBAlert #  
notification as soon as the first state change occurred. During  
an event a number of different states can be transitioned to  
before the final event occurs. If a read back is implemented  
rapidly by the host a successive SMBAlert# could be triggered  
by the transitioning state of the power supply. In order to avoid  
successive SMBAlert# s and read back and also to avoid  
reading a transitioning state, it is prudent to wait more than 2  
seconds after the receipt of an SMBAlert# before executing a  
read back. This delay will ensure that only the final state of the  
power supply is captured.  
Block write format:  
1
S
7
1
Wr  
1
A
8
1
A
Slave address  
Command Code  
8
1
A
8
1
A
8
1
A
Byte count = N  
Data 1  
Data 2  
8
……….  
1
A
8
1
A
8
PEC  
1
A
1
P
Successive read backs: Successive read backs to the power  
supply should not be attempted at intervals faster than every  
one second. This time interval is sufficient for the internal  
processors to update their data base so that successive reads  
provide fresh data.  
Data 48  
Block read format:  
1
S
7
1
1
A
8
1
A
Slave address  
Wr  
Command Code  
1
Sr  
7
1
Rd  
1
A
Invalid commands or data: The power supply notifies the  
MASTER if a non-supported command has been sent or invalid  
data has been received. Notification is implemented by setting  
the appropriate STATUS and ALARM registers and setting the  
SMBAlert# flag.  
Slave Address  
8
1
A
8
1
A
8
1
A
Byte count = N  
Data 1  
Data 2  
8
……….  
1
A
8
1
A
8
PEC  
1
1
P
If a non-supported read is requested the power supply will  
return all 0x00h.  
Data 48  
NoAck  
February 7, 2014  
©2013 General Electric Company. All rights reserved.  
Page 9  