Data Sheet  
Austin SuperlynxTM II SIP Non-isolated Power Modules:  
March 31, 2008  
2.4 – 5.5Vdc input; 0.75Vdc to 3.3Vdc Output; 16A output current  
Feature Description  
VIN+  
MODULE  
Remote On/Off  
R
pull-up  
Austin SuperLynxTM II SIP power modules feature an  
On/Off pin for remote On/Off operation. Two On/Off logic  
options are available in the Austin SuperLynxTM II series  
modules. Positive Logic On/Off signal, device code suffix  
“4”, turns the module ON during a logic High on the  
On/Off pin and turns the module OFF during a logic Low.  
Negative logic On/Off signal, no device code suffix, turns  
the module OFF during logic High and turns the module  
ON during logic Low.  
I
ON/OFF  
ON/OFF  
+
PWM Enable  
V
ON/OFF  
R1  
R2  
Q2  
CSS  
Q1  
For positive logic modules, the circuit configuration for  
using the On/Off pin is shown in Figure 28. The On/Off  
pin is an open collector/drain logic input signal (Von/Off)  
that is referenced to ground. During a logic-high (On/Off  
pin is pulled high internal to the module) when the  
transistor Q1 is in the Off state, the power module is ON.  
Maximum allowable leakage current of the transistor  
when Von/off = VIN,max is 10µA. Applying a logic-low  
when the transistor Q1 is turned-On, the power module is  
OFF. During this state VOn/Off must be less than 0.3V.  
When not using positive logic On/off pin, leave the pin  
unconnected or tie to VIN.  
GND  
_
Figure 29. Circuit configuration for using negative  
logic On/OFF  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally once  
the output current is brought back into its specified range.  
The typical average output current during hiccup is 3.5A.  
VIN+  
MODULE  
R2  
Input Undervoltage Lockout  
ON/OFF  
Q2  
+
R1  
At input voltages below the input undervoltage lockout  
limit, module operation is disabled. The module will begin  
to operate at an input voltage above the undervoltage  
lockout turn-on threshold.  
V
ON/OFF  
I
ON/OFF  
PWM Enable  
R3  
Q1  
Q3  
CSS  
Overtemperature Protection  
To provide over temperature protection in a fault  
R4  
condition, the unit relies upon the thermal protection  
feature of the controller IC. The unit will shutdown if the  
thermal reference point Tref, exceeds 125oC (typical), but  
the thermal shutdown is not intended as a guarantee that  
the unit will survive temperatures beyond its rating. The  
module will automatically restart after it cools down.  
GND  
_
Figure 28. Remote On/Off Implementation.  
For negative logic On/Off devices, the circuit  
configuration is shown is Figure 29. The On/Off pin is  
pulled high with an external pull-up resistor (typical Rpull-  
up = 68k, +/- 5%). When transistor Q1 is in the Off state,  
logic High is applied to the On/Off pin and the power  
module is Off. The minimum On/off voltage for logic High  
on the On/Off pin is 1.5Vdc. To turn the module ON,  
logic Low is applied to the On/Off pin by turning ON Q1.  
When not using the negative logic On/Off, leave the pin  
unconnected or tie to GND.  
LINEAGE POWER  
12