Data Sheet
Austin LynxTM II 12 V SMT Non-Isolated Power Modules:
May 19, 2009
8.3 – 14.0 Vdc Input; 0.75Vdc to 5.5Vdc Output; 10A output current
Design Considerations (continued)
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards,
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE
0850:2001-12 (EN60950-1) Licensed.
Output Filtering
The Austin LynxTM II 12VSMT module is designed for low
output ripple voltage and will meet the maximum output
ripple specification with 1 µF ceramic and 10 µF tantalum
capacitors at the output of the module. However,
additional output filtering may be required by the system
designer for a number of reasons. First, there may be a
need to further reduce the output ripple and noise of the
module. Second, the dynamic response characteristics
may need to be customized to a particular load step
change.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power module
has extra-low voltage (ELV) outputs when all inputs are
ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 15A in the positive
input lead.
To reduce the output ripple and improve the dynamic
response to a step load change, additional capacitance at
the output can be used. Low ESR polymer and ceramic
capacitors are recommended to improve the dynamic
response of the module. For stable operation of the
module, limit the capacitance to less than the maximum
output capacitance as specified in the electrical
specification table.
LINEAGE POWER