欢迎访问ic37.com |
会员登录 免费注册
发布采购

APXW005A0X3-SRZ_1010 参数 Datasheet PDF下载

APXW005A0X3-SRZ_1010图片预览
型号: APXW005A0X3-SRZ_1010
PDF下载: 下载PDF文件 查看货源
内容描述: 9-36V ProLynxTM 5A :非隔离DC-DC电源模块9VDC -36VDC输入; 3VDC到18VDC输出; 5A至2.5A输出电流 [9-36V ProLynxTM 5A: Non-Isolated DC-DC Power Modules 9Vdc –36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A Output Current]
分类和应用: 电源电路
文件页数/大小: 21 页 / 5069 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第8页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第9页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第10页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第11页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第13页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第14页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第15页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第16页  
Preliminary Data Sheet  
October 28, 2010  
9-36V ProLynxTM 5A: Non-isolated DC-DC Power Modules  
9 – 36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A output current  
Feature Descriptions  
MODULE  
Remote Enable  
D2  
+5V  
The 9-36V ProLynxTM modules feature an On/Off pin for  
remote On/Off operation. Two On/Off logic options are  
available. In the Positive Logic On/Off option, (device  
code suffix “4” – see Ordering Information), the module  
turns ON during a logic High on the On/Off pin and turns  
OFF during a logic Low. With the Negative Logic  
On/Off option, (no device code suffix, see Ordering  
Information), the module turns OFF during logic High  
and ON during logic Low. The On/Off signal is always  
referenced to ground.  
VIN+  
22K  
D1  
Rpullup  
22K  
PWM Enable  
Q2  
I
ON/OFF  
ON/OFF  
+
22K  
22K  
V
ON/OFF  
CSS  
Q1  
GND  
_
For positive logic modules, the circuit configuration for  
using the On/Off pin is shown in Figure 32. When the  
external transistor Q1 is in the OFF state, the ON/OFF  
pin is pulled high and transistor Q2 is OFF leading to Q3  
also being OFF which turns the module ON. The  
external resistor Rpullup (100k recommended) must be  
sized so that VON/OFF is never more than 12V when Q1  
is OFF. In particular, if Vpullup is made the same as the  
input voltage Vin, the resistor Rpullup must be large  
enough so that VON/OFF is never more than 12V.  
Figure 33. Circuit configuration for using negative  
On/Off logic.  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally  
once the output current is brought back into its specified  
range. The 9-36V ProLynx modules employ an  
innovative, patent pending, ‘AutoLimit’ capability. This  
results in automatic scaling of current limit with output  
voltage through an inverse relationship of the current  
limit threshold with the output voltage. This feature  
shown graphically in Fig. 34, allows higher output  
currents to be drawn from the module at lower output  
voltages thereby optimizing the power delivery  
capability of the module.  
For negative logic On/Off modules, the circuit  
configuration is shown in Fig. 33. When the external  
transistor Q1 is in the ON state, the ON/OFF pin is  
pulled low causing transistor Q2 to be OFF and the  
module to be turned ON. To turn the module OFF, Q1 is  
turned OFF, causing the ON/OFF pin to be pulled high  
turing Q2 ON and the module to be turned OFF.  
Leaving the On/Off pin floating will leave the module in  
an OFF state.  
5.5  
Vpullup  
MODULE  
5
+5V  
Rpullup  
4.5  
4
22K  
I
ON/OFF  
Q2  
PWM Enable  
ON/OFF  
+
22K  
3.5  
3
Q3  
42K  
22K  
V
ON/OFF  
CSS  
Q1  
2.5  
2
GND  
_
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18  
Figure 32. Circuit configuration for using positive  
On/Off logic.  
Output Voltage (V)  
Figure 34. Graph showing maximum output current  
capability at different output voltages.  
Over Temperature Protection  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shutdown if the overtemperature threshold of 130oC is  
exceeded at the thermal reference point Tref. The  
thermal shutdown is not intended as a guarantee that  
the unit will survive temperatures beyond its rating.  
LINEAGE POWER  
12