LM230WF5
Liquid Crystal Display
Product Specification
3-4 Signal timing specifications
This is the signal timing required at the input of the User connector. All of the interface signal timing should be
satisfied with the following specifications for it’s proper operation.
Table 7. Timing table
ITEM
Symbol
Min
Typ
Max
Unit
Note
Period
tCLK
-
11.11
60
13.89
72
16.7
90
ns
DCLK
Frequency
Period
5
MHz
tCLK
tCLK
tHP
tHV
tHB
fH
1024
960
64
1088
960
128
66
1120
960
160
83
Horizontal Valid
Horizontal Blank
Frequency
Hsync
64
KHz
Width
tWH
tHBP
tHFP
tVP
tVV
tVB
fV
16
32
48
tCLK
Horizontal Back Porch
Horizontal Front Porch
Period
32
48
64
16
48
48
1090
1080
10
1100
1080
20
1160
1080
80
tHP
tHP
tHP
Hz
Vertical Valid
Vertical Blank
Frequency
Vsync
50
60
75
Width
tWV
tVBP
tVFP
2
4
16
tHP
Vertical Back Porch
Vertical Front Porch
5
8
32
3
8
32
Note: Hsync period and Hsync width-active should be even number times of tCLK. If the value is odd number
times of tCLK, display control signal can be asynchronous. In order to operate this LCM a Hsync,
Vsyn, and DE(data enable) signals should be used.
1. The performance of the electro-optical characteristics may be influenced by variance of the vertical
refresh rates.
2. Vsync and Hsync should be keep the above specification.
3. Hsync Period, Hsync Width, and Horizontal Back Porch should be any times of of character
number(4).
4. The polarity of Hsync, Vsync is not restricted.
5. The Max frequency of 1920X1080 resolution is 82.5Mhz
Ver. 0.0
Feb. 16, 2012
14 / 30