ABSOLUTE MAXIMUM RATINGS
OPERATING RANGES
Storage Temperature . . . . . . . . . . . . . .-65°C to +150°C
Commercial (C) Devices
Ambient Temperature with
Power Applied . . . . . . . . . . . . . . . . . .-55°C to +125°C
Ambient Temperature (T ) . . . . . . . . . . . 0°C to +75°C
A
Supply Voltage (V ) with
CC
Respect to Ground. . . . . . . . . . . . . +4.75 V to +5.25 V
Supply Voltage with Respect
to Ground . . . . . . . . . . . . . . . . . . . . . -0.5 V to +7.0 V
Industrial (I) Devices
DC Input Voltage . . . . . . . . . . . .-0.5 V to V + 0.5 V
CC
DC Output or I/O Pin
Ambient Temperature (T ) . . . . . . . . . -40°C to +85°C
A
Voltage . . . . . . . . . . . . . . . . . . .-0.5 V to V + 0.5 V
CC
Supply Voltage (V ) with
CC
Static Discharge Voltage . . . . . . . . . . . . . . . . . 2001 V
Respect to Ground. . . . . . . . . . . . . . . +4.5 V to +5.5 V
Operating ranges define those limits between which the func-
tionality of the device is guaranteed.
Latchup Current (T = -40°C to +85°C) . . . . . . 100 mA
A
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
Programming conditions may differ.
DC CHARACTERISTICS OVER COMMERCIAL AND INDUSTRIAL OPERATING
RANGES
Parameter
Symbol
Parameter Description
Output HIGH Voltage
Test Conditions
Min
Max
Unit
V
I
= -6 mA
3.84
V = V or V
OH
IN IH
IL
V
OH
V = Min
I
I
= -20 µA
V -0.1
CC
V
CC
OH
= 16 mA
= 6 mA
= 20 µA
0.5
0.33
0.1
V
OL
V = V or V
IN IH
IL
V
Output LOW Voltage
I
V
OL
OL
V = Min
CC
I
V
OL
Guaranteed Input Logical HIGH Voltage for all Inputs
(Notes 1, 2)
V
Input HIGH Voltage
Input LOW Voltage
2.0
V
V
IH
Guaranteed Input Logical LOW Voltage for all Inputs
(Notes 1, 2)
V
0.9
IL
I
Input HIGH Leakage Current
V = V , V = Max (Note 3)
IN CC CC
10
-10
10
µA
µA
µA
µA
mA
µA
mA
IH
I
Input LOW Leakage Current
V = 0 V, V = Max (Note 3)
IL
IN
CC
I
Off-State Output Leakage Current HIGH
Off-State Output Leakage Current LOW
Output Short-Circuit Current
V
= V , V = Max, V = V or V (Note 3)
OZH
OUT CC CC
IN IH
IL
I
V
= 0 V, V = Max, V = V or V (Note 3)
-10
-150
30
OZL
OUT
CC
IN IH
IL
I
V
= 0.5 V, V = Max (Note 4)
-5
SC
OUT
CC
f = 0 MHz
Outputs Open (I
= 0 mA)
OUT
I
Supply Current
CC
V = Max
CC
f = 15 MHz
120
Notes:
1. These are absolute values with respect to device ground, and all overshoots due to system or tester noise are included.
2. Represents the worst case of HC and HCT standards, allowing compatibility with either.
3. I/O pin leakage is the worst case of I and I
(or I and I
).
4. Not more than one output should be shorted at a time, and the duration of the short-circuit should not exceed one second.
IL OZL
IH OZH
V
= 0.5 V has been chosen to avoid test problems caused by tester ground degradation.
OUT
22
PALCE22V10Z-25 (Com’l, Ind)