MACH211 AND MACH211SP (CONTINUED)
SWITCHING CHARACTERISTICS OVER OPERATING RANGES
1
-6
-7
-10
-12
-14
-15
-18
Parameter
Symbol
Parameter Description
Min Max Min Max Min Max Min Max Min Max Min Max Min Max Unit
Asynchronous Reset to Registered or Latched
Output
9
9
9.5
9.5
15
15
16
16
19.5
19.5
20
20
24
24
ns
t
AR
Asynchronous Reset Width (Note 2)
4
4
5
5
10
10
12
10
14.5
10
15
10
18
12
ns
ns
t
ARW
Asynchronous Reset Recovery Time (Note 2)
t
ARR
Asynchronous Preset to Registered or Latched
Output
ns
t
AP
Asynchronous Preset Width (Note 2)
4
4
5
5
10
10
12
10
14.5
10
15
10
18
12
ns
ns
ns
ns
ns
ns
ns
ns
t
APW
Asynchronous Preset Recovery Time (Note 2)
Input, I/O, or Feedback to Output Enable
Input, I/O, or Feedback to Output Disable
t
APR
9
9
9.5
9.5
10
10
0
10
10
10
10
0
12
12
10
10
0
14
14
10
10
0
15
15
10
10
0
18
18
10
10
0
t
EA
t
ER
t
Increase for Powered-down Macrocell (Note 3)
10
10
0
t
PD
LP
t Increase for Powered-down Macrocell (Note 3)
t
S
LPS
t
Increase for Powered-down Macrocell (Note 3)
Increase for Powered-down Macrocell (Note 3)
t
CO
LPCO
t
10
10
10
10
10
10
10
t
EA
LPEA
Notes:
1. See “Switching Test Circuit” in the General Information Section of the Vantis 1999 Data Book.
2. These parameters are not 100% tested, but are evaluated at initial characterization and at any time the design is modified where
this parameter may be affected.
3. If a signal is powered-down, this parameter must be added to its respective high-speed parameter.
4. MACH211 t = 7 ns. MACH211SP t = 7.5 ns.
GO
GO
5. MACH211, commercial t = 7 ns.
GO
6. The faster -18 t , t , t , apply to MACH211 only, not MACH211SP.
GO PDL ICO
28