Technical Specifications
Clocksꢀandꢀtriggers
10ꢀMHzꢀsystemꢀclockꢀ(PXI_CLK10)
Maximum slot-to-slot skew
Accuracy
155 ps
30 ppm
Output amplitude (10 MHz REF Out BNC)
1 V pk-pk ±20% square-wave into 50 Ω
2 V pk-pk unloaded
50 Ω ±5 Ω
Output impedance (10 MHz REF Out BNC)
100ꢀMHzꢀsystemꢀclockꢀ(ꢀPXIe_CLK100)
Maximum slot-to-slot skew
Accuracy
125 ps
30 ppm
Externalꢀ10ꢀMHzꢀclockꢀsourceꢀinputꢀrequirements
Frequency input
10 MHz ±100 PPM
Input signal (10 MHz REF In BNC)
Input signal (PXI timing slot PXI_CLK10_IN)
PXIꢀstarꢀtrigger
100 mVPP to 5 VPP (square-wave or sine-wave)
5 V or 3.3 V TTL signal
Maximum slot-to-slot skew
PXIꢀdifferentialꢀstarꢀtriggers
Maximum slot-to-slot skew
Maximum differential skew
Frontꢀpanelꢀtriggersꢀ(trigꢀ1ꢀandꢀtrigꢀ2ꢀSMBs)
Direction control
250 ps
150 ps
25 ps
Input or output (configurable)
3.3 V CMOS (TTL compatible, 5 V tolerant)
50 Ω (typ)
Output level
Output impedance
Output trigger source
PXI_Trig0 - PXI_Trig7 (Segment 2)
3.3 V CMOS (TTL compatible, 5 V tolerant)
3 kΩ (typ)
Input level
Input impedance
Input trigger destination
Input threshold
PXI_Trig0 - PXI_Trig7 (Segment 2)
1.65 V (typ)
Minimum swing
250 mV (typ)
Minimum pulse width
100 ns (typ)
Environmentalꢀcharacteristics1,ꢀ2
Operating
Storage
Temperature
Altitude
0˚C to 55˚C
-40˚C to 70˚C
Up to 10,000 ft (3048 m)
Up to 15,000 ft (4572 m)
Humidity
Type-tested at 95%, RH (non-condensing)
Vibration
Operating random vibration: type-tested at 5 to 500 Hz, 0.21 g rms
Survival random vibration: type-tested at 5 to 500 Hz, 2.09 g rms
Acousticalꢀemissionsꢀ(referencedꢀtoꢀ1ꢀpW)
Autoꢀfanꢀ(25˚Cꢀambient)
Highꢀfan
69 dBA
77 dBA
Sound pressure level3
Sound power
53 dBA
59 dBA
1. Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environ-
mental stresses of storage, transportation and end-use. Those stresses include but are not limited to temperature, humidity, shock, vibration, altitude and
power line conditions.
2. Test Methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3
3. At operator position