09 | Keysight | M9018B and M9019A PXIe Chassis - Data Sheet  
Technical Specifications  
Powerꢀsupplyꢀcharacteristics,ꢀcontinued  
DCꢀsupplies  
M9018B  
M9019A  
Voltage  
Maximumꢀꢀcurrent1  
Maximumꢀꢀcurrent3  
Loadꢀ  
Maximumꢀrippleꢀandꢀnoiseꢀ(20ꢀMHzꢀBW)  
regulation  
45ꢀ˚C,ꢀ<10kft 50ꢀ˚C,ꢀ10kft 45ꢀ˚C,ꢀ<10kft 50ꢀ˚C,ꢀ10kft  
+3.3 V  
+5 V  
70 A  
60 A2  
57.4 A2  
4 A  
67 A  
70 A  
60 A4  
52.5 A4  
4 A  
67 A  
52.5 A4  
45 A4  
4 A  
5%  
5%  
5%  
5%  
5%  
1.5% (pk-pk)  
1% (pk-pk)  
1% (pk-pk)  
1% (pk-pk)  
50 mV (pk-pk)  
52.5 A2  
49 9 A2  
4 A  
+12 V  
-12 V  
5 VAUX  
2 A  
2 A  
2 A  
2 A  
Backplaneꢀpinꢀcurrentꢀcapacity  
Slot  
+3.3ꢀV  
9 A  
+5ꢀV  
9 A  
+12ꢀV  
11 A  
4 A  
-ꢀ12ꢀV  
0 A  
5ꢀVAUX  
1 A  
System controller slot  
System timing/PXIe slot  
PXIe hybrid slot  
6 A  
0 A  
0 A  
1 A  
6 A  
6 A  
-4 A  
1 A  
1 A  
Chassisꢀcoolingꢀandꢀpowerꢀdissipationꢀcharacteristics  
Slot airflow direction  
Bottom of module to top of module  
Chassis cooling intake  
Chassis cooling exhaust  
Chassis cooling fans  
Bottom of front bezel, side panels, and bottom panel of chassis  
Rear of chassis  
Three 186 cfm fans on rear panel with HIGH/AUTO speed selector  
Power dissipation, system slot  
Power dissipation, user slot  
Power dissipation, timing slot  
140 W max  
42 W max5  
42 W max5  
1. The total power supplied for all rails must not exceed 708 W (100-120 V) or 858 W (200-240 V).  
2. The total power supplied for 5 V and 12 V rails must not exceed 689W at 45 °C,<10kft, or 599W at 50 °C, 10kft.  
3. The total power supplied for all rails must not exceed 650W (100-120 V) or 800 W (200-240 V).  
4. The total power supplied for 5 V and 12 V rails must not exceed 630W at 45 °C,<10kft, or 540 W at 50 °C, 10kft.  
5. Maximum per slot power dissipation at 55 °C with 15 °C temperature rise; requires: a) that the chassis. bottom is not blocked (1U rack space  
below or sitting on bench with feet extended) OR b) two air inlet modules in slots 9, 10, or 11, and a slot blocker in empty controller slots.  
Module cooling can be impacted by each module’s resistance to air flow.