4 | Keysight | N9923A FieldFox RF Vector Network Analyzer - Data Sheet  
FieldFox RF Vector Network Analyzer (continued)  
Description  
Information  
Display range  
Log magnitude S11 or S22  
Log magnitude S21 or S12  
Log magnitude resolution  
Phase  
-1000 to 1000 dB  
-1000 to 1000 dB  
0.01 dB  
-180 to +180 degrees  
0.01 degrees  
1.01 to 1000  
0.01  
Phase resolution  
VSWR  
VSWR resolution  
Averaging  
2 to 999  
Two methods: sweep and point averaging  
Number of traces  
Data markers  
Four traces available. Tr1, Tr2, Tr3, Tr4  
Each trace has six independent markers that can be displayed simultaneously. Delta markers are available for  
each marker.  
Marker formats  
Default marker format is the trace format. In Smith chart or polar format,  
[Real +Imag] or [Mag and Phase] formats are also available.  
Marker functions  
Peak, Next Peak, Peak Left, Peak Right, MkrCenter, Min Search, Peak Excursion, Peak Threshold, Target,  
Bandwidth, Tracking  
Sweep type  
Linear  
Sweep time  
Set sweep time in seconds  
Continuous, single  
Sweep trigger  
Display formats  
Single-trace  
Dual-trace overlay (both traces on one graticule)  
Dual-trace split (each trace on separate graticules)  
Three-trace split (each trace on separate graticules)  
Quad-trace split (each trace on separate graticules)  
Display data  
Trace math  
Scale  
Display data, memory, data and memory, or data math  
Vector division or subtraction of current linear measurement values and memory data.  
Autoscale, scale, reference level, reference position  
Autoscale: Automatically selects scale resolution and reference value to center the trace. Autoscale all scales  
all visible traces.  
Title  
Add custom titles to the display.  
Limit lines  
Define test limit lines that appear on the display for go/no go testing. Lines may be any combination of hori-  
zontal, sloping lines, or discrete data points. Each trace can have its own limit line. Limit lines can be fixed or  
relative, and can be built from existing traces.  
Calibration Types  
CalReady  
Each FieldFox is calibrated at the test port.  
Frequency response  
Simultaneous magnitude and phase correction of frequency response errors for either reflection or transmis-  
sion measurements.  
Enhanced response  
1-port calibration  
Corrects for frequency response and source match for transmission measurements, and corrects for reflec-  
tion frequency response, directivity and source match errors for reflection measurements.  
Corrects for directivity, frequency response, and source match errors.