32 | Keysight | FieldFox Handheld Analyzers 4/6.5/9/14/18/26.5/32/44/50 GHz - Data Sheet
The performance listed in these sections below applies to the spectrum analyzer capabilities available in the following models:
– FieldFox RF & microwave analyzers: N9913A, N9914A, N9915A, N9916A, N9917A, N9918A
N9950A, N9951A, N9952A
– FieldFox microwave spectrum analyzers: N9935A, N9936A, N9937A, N9938A
N9960A, N9961A, N9962A
See FieldFox Configuration Guide for option information. Many capabilities listed in this Data Sheet require options.
Spectrum Analyzer IF Output
Description
Center Frequency
IF bandwidth
Connector
33.75 MHz
5 MHz (default), 25 MHz
SMB male
Conversion loss
0 to 27 dB nominal
The loss increases approximately linearly as frequency increases, with ~27 dB loss at 26.5 GHz. Conversion loss is
defined from RF input to SA output with −10 dBm input power, 0 dB attenuation, and preamp off.
Preamplifier
Nominal
Frequency range
Gain
Full band (100 kHz to maximum frequency of instrument)
N991xA, N993xA
N995xA, N996xA
+20 dB, 100 kHz to 26.5 GHz
+20 dB, 100 kHz to 7.5 GHz
+15 dB, > 7.5 to 50 GHz
Interference Analyzer and Spectrogram
Description
Spectrogram display
Waterfall angle
Overlay, full screen, top, or bottom with active trace
Moderate, steep, gradual, wide angle
Time, delta time
Markers
Trace playback and recording
Record all spectrum analyzer measurements
Store data internally or on USB or SD card
Playback recorded data using FieldFox
Frequency mask trigger allows recording to occur upon trigger
Channel Scanner
Description
Scan Mode
Range or custom list
Display Type
Bar chart vertical, bar chart horizontal, channel power, strip chart, chart overlay, scan & listen
Time with geo tagging
Data logging mode
Trace playback and recording
Record channel power measurement
Store data internally or USB or SD card in .csv or .kml format
Playback recorded data using FieldFox
Data in .kml format can be exported to Google Earth