23 | Keysight | FieldFox Handheld Analyzers 4/6.5/9/14/18/26.5/32/44/50 GHz - Data Sheet  
Spectrum Analyzer (continued)  
Amplitude accuracy and range specifications  
Amplitude range  
Measurement range  
Input attenuator range  
Preamplifier  
DANL to +20 dBm  
0 to 30 dB, in 5 dB steps  
Nominal  
Frequency range  
Gain  
Full band (100 kHz to maximum frequency of instrument)  
N991xA, N993xA  
+20 dB, 100 kHz to 26.5 GHz  
+20 dB, 100 kHz to 7.5 GHz  
+15 dB, > 7.5 to 50 GHz  
DC  
N995xA, N996xA  
Max safe input level  
N991xA, N993xA  
N995xA, N996xA  
Display range  
Average CW power  
+27 dBm, 0.5 watts  
+25 dBm, 0.3 watts  
± 50 VDC  
± 40 VDC  
Log scale  
10 divisions  
0.01 to 100 dB/division in 0.01 dB steps  
10 divisions  
Linear scale  
Scale units  
dBm, dBmV, dBµV.dBmA, dBµA, W, V, A, dBµV/m, dBµA/m, dBG, dBT  
50 MHz absolute amplitude accuracy (dB)  
0 dB attenuation, input signal 0 to -35 dBm, peak detector, preamplifier off, 300 Hz RBW, all settings auto-coupled, -10 to 55 °C. No warm-up required.  
Spec (-10 to 55 ºC)  
Typical (-10 to 55 ºC)  
N991xA, N993xA  
± 0.30  
± 0.10  
0 dB attenuation, input signal -5 to -35 dBm, peak detector, preamplifier off, 300 Hz RBW, all settings auto-coupled, -10 to 55 °C. No warm-up required.  
Spec (-10 to 55 ºC)  
Typical (-10 to 55 ºC)  
N995xA, N996xA  
± 0.45  
± 0.20  
Total absolute amplitude accuracy (dB)  
10 dB attenuation, input signal -15 to -5 dBm, peak detector, preamplifier off, 300 Hz RBW, all settings auto-coupled, includes frequency response  
uncertainties. No warm-up required.  
N991xA, N993xA1  
100 kHz to 18 GHz  
> 18 to 26.5 GHz  
N995xA, N996xA 2  
9 to 100 kHz  
Spec (23 ± 5 °C)  
± 0.80  
Spec (-10 to 55 °C)  
± 1.00  
Typical (23 ± 5 °C)  
± 0.35  
Typical (-10 to 55 °C)  
± 0.50  
± 0.60  
± 1.00  
± 1.20  
± 0.50  
Spec (23 ± 5 °C)  
± 1.60  
Spec (-10 to 55 °C)  
± 2.50  
Typical (23 ± 5 °C)  
± 0.60  
Typical (-10 to 55 °C)  
± 1.30  
> 100 kHz to 2 MHz  
> 2 to 15 MHz  
± 1.30  
± 1.90  
± 0.60  
± 0.80  
± 1.00  
± 1.20  
± 0.30  
± 0.50  
> 15 MHz to 32 GHz  
> 32 to 40 GHz  
± 0.80  
± 1.00 3  
± 0.30  
± 0.50  
± 0.90  
± 1.40  
± 0.50  
± 0.70  
> 40 to 43 GHz  
± 1.30  
± 2.00  
± 0.50  
± 0.70  
> 43 to 50 GHz  
± 1.40  
± 2.70  
± 0.50  
± 0.90  
1. 9 to 100 kHz: 0.4 dB (nominal) preamp on or off; applicable only for serial number with prefix of MY5607/SG5607/US5607 and FieldFox upgraded with  
Option N9910HU-100/200/300/400.  
2. Also applies for preamplifier on or off for these models, for measurement frequencies > 100 kHz.  
3. Increase by 0.2 dB between 18 and 32 GHz.  