33 | Keysight | Infiniium 90000 Series Oscilloscopes - Data Sheet  
Infiniium 90000A Series Oscilloscopes (Continued)  
Performance characteristics (Continued)  
Computer system and peripherals, I/O ports (Continued)  
I/O ports (Continued)  
PCI EXPRESS  
GPIB  
PCI EXPRESS x4 link, enabled by sockets (optional- Option 823)  
IEEE 488.2, fully programmable (optional – Option 805)  
RS-232 (serial)  
Parallel  
COM1, printer and pointing device support  
Centronics printer port  
PS/2  
Two ports. Supports PS/2 pointing and input devices.  
USB 2.0 hi-speed (host)  
USB 2.0 hi-speed (device)  
Dual-monitor video output  
Auxiliary output  
Trigger output  
Three USB 2.0 hi-speed host ports on front panel plus four USB 2.0 Hi-Speed host ports on rear panel  
One USB 2.0 hi-speed device port on rear panel that enables USB instrument control  
15 pin XGA (1024x768), full color output of scope waveform display or dual monitor video output  
DC (± 2.4 V); square wave (~715 Hz and ~456 MHz); trigger output (255 mV p-p into 50)  
5 V 50 Ω back-terminated  
Time base reference output  
10 MHz filtered sine wave with all harmonics ≤ –40 dBc. Amplitude into 50 Ω: 800 mV p-p to 1.26 V p-p (4 dBm  
± 2 dB) if derived from internal reference. Tracks external reference input amplitude ± 1 dB if applied and selected.  
Must be 10 MHz, input Z0 = 50 Ω. Minimum 500 mV p-p (–2 dBm), maximum 2.0 V p-p (+10 dBm).  
Functional Class C  
Time base reference input  
LXI compliance  
General characteristics  
Temperature  
Humidity  
Operating: 5 °C to +40 °C; Non-operating: –40 °C to +65 °C  
Operating: up to 95% relative humidity (non-condensing) at +40 °C; Non-operating: up to 90% relative humidity at  
+65 °C  
Altitude  
Vibration  
Power  
Operating: up to 4,000 meters (12,000 feet); Non-operating: up to 15,300 meters (50,000 feet)  
Operating random 0.21 g(rms), non-operating random 2.0 g(rms), swept sins (0.50 g(rms))  
100 to 240 VAC at 50/60 Hz; maximum input power 800 W  
Net: 20 kg (44 lbs.)  
Weight  
Shipping: 27.4 kg (60 lbs.)  
Dimensions (excluding handle)  
Safety  
Height: 283 mm (11.13 inch); Width: 432 mm (17.02 inch); Depth: 506 mm (19.91 inch)  
Meets IEC 61010-1 +A2, CSA certified to C22.2 No.1010.1, self-certified to UL 3111  
1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period, and ± 5 °C from annual calibration  
temperature�  
2. Full scale is defined as 8 vertical divisions. Magnification is used below 5 mV/div. Below 5 mV/div, full-scale is defined as 40 mV. The major scale settings are  
5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V�  
3� Vertical resolution for 8 bits = 0�4% of full scale, for 12 bits = 0�024% of full scale�  
4� 13 GHz DSP enhanced bandwidth not applicable at 5 mV/div�  
5. FFT amplitude readings are affected by scope and probe bandwidth limitations and input amplifiers roll-off (e.g. 3 dB roll-off at specified bandwidth of  
scope/probe)�  
6� The FFT signal to noise ratio varies with volts/division setting, memory depth and use of time or frequency averaging�  
7a. Noise is the displayed noise floor. SlewRate is the displayed slew rate of the signal at the threshold crossings. Sample rate = max, sin(x)/x interpolation  
enabled�  
7b. Measurement threshold = fixed voltage at 50% level.  
7c. Time ranges ≤ 10 µs.  
8� Values represent time error between two edges on a single channel� Standard deviation value refers to the standard deviation of 256 consecutive  
measurements performed using an individual instrument. Reading is the displayed DTMA measurement value. TimeScaleAccy is the oscilloscope’s specified  
time scale accuracy�  
9. Internal edge trigger mode. Trigger threshold = fixed voltage at 50% level. The slew rate independent value in the formula represents the traditional trigger  
jitter�  
10. Requires Option 010 user defined function.  
11� 11�8 GHz analog bandwidth at 5 mV/div for DSO91304A and DSO91204A models�  
12� Typically triggers as low as 5 mV/div sensitivity�  
13� Measurement histograms require EZJIT license�  
 复制成功!