30 | Keysight | Infiniium 90000 Series Oscilloscopes - Data Sheet  
Infiniium 90000A Series Oscilloscopes (Continued)  
Performance characteristics (Continued)  
Measurements and math  
Maximum measurement update  
rate  
Measurement modes  
Waveform measurements  
Voltage  
> 42,000 measurement/sec (one measurement turned on)  
> 122,000 measurement/sec/measurement (five measurements turned on)  
Standard, Measure All edges mode  
Peak to peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, preshoot, upper, middle, lower  
Time  
Rise time, fall time, period, frequency, positive width, negative width, duty cycle, burst width, Tmin, Tmax, Tvolt,  
setup time (requires Option 002, 004, or 070 standard on DSA models), hold time (requires Option 002, 004, or 070  
standard on DSA models), channel-to-channel delta time, channel-to-channel phase  
Mixed  
Area, slew rate  
Frequency domain  
Level qualification  
Eye-diagram measurements  
Jitter analysis measurements  
Clock  
FFT frequency, FFT magnitude, FFT delta frequency, FFT delta magnitude  
Any channels that are not involved in a measurement can be used to level-qualify all timing measurements  
Eye height, eye width, eye jitter, crossing percentage, Q factor, and duty-cycle distortion  
Fast eye rendering increases speed of the eye diagram rendering  
Requires Option 002 (or E2681A), 004 (or N5400A), or 070 (or N8823A). Standard on DSA Series.  
Data  
Time interval error (TIE) data with TIE band, high, low-pass filter, data rate, unit interval, clock recovery rate, burst  
time, burst period, burst interval  
Timing  
Two sources: Setup time, hold time, phase, advanced  
One source: Period, frequency, + width, width, duty cycle, burst width, rise time, fall time, slew rate  
Statistics  
Displays the current, mean, minimum, maximum, range (max-min), standard deviation, number of measurements  
value for the displayed automatic measurements  
Histograms  
Source  
Waveform or measurement 13  
Orientation  
Vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defined  
using waveform markers  
Measurements  
Mean, standard deviation, mean ± 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total hits, peak (area of  
most hits), X scale hits, and X offset hits  
1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period, and ± 5 °C from annual calibration  
temperature�  
2. Full scale is defined as 8 vertical divisions. Magnification is used below 5 mV/div. Below 5 mV/div, full-scale is defined as 40 mV. The major scale settings are  
5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V�  
3� Vertical resolution for 8 bits = 0�4% of full scale, for 12 bits = 0�024% of full scale�  
4� 13 GHz DSP enhanced bandwidth not applicable at 5 mV/div�  
5. FFTamplitudereadingsareaffectedbyscopeandprobebandwidthlimitationsandinputamplifiersroll-off(e.g.3dBroll-offatspecifiedbandwidthofscope/probe).  
6� The FFT signal to noise ratio varies with volts/division setting, memory depth and use of time or frequency averaging�  
7a. Noise is the displayed noise floor. SlewRate is the displayed slew rate of the signal at the threshold crossings. Sample rate = max, sin(x)/x interpolation  
enabled�  
7b. Measurement threshold = fixed voltage at 50% level.  
7c. Time ranges ≤ 10 μs.  
8� Values represent time error between two edges on a single channel� Standard deviation value refers to the standard deviation of 256 consecutive  
measurements performed using an individual instrument. Reading is the displayed DTMA measurement value. TimeScaleAccy is the oscilloscope’s specified  
time scale accuracy�  
9. Internal edge trigger mode. Trigger threshold = fixed voltage at 50% level. The slew rate independent value in the formula represents the traditional trigger  
jitter�  
10. Requires Option 010 user defined function.  
11� 11�8 GHz analog bandwidth at 5 mV/div for DSO91304A and DSO91204A models�  
12� Typically triggers as low as 5 mV/div sensitivity�  
13� Measurement histograms require EZJIT license�  