16 | Keysight | N1090A, N1092A/B/C/D/E and N1094A/B DCA-M Optical and Electrical Sampling Oscilloscopes - Data Sheet  
N1092/4 Horizontal Timebase Specifications  
Item  
Description  
Scale factor  
Minimum  
Maximum  
Sample delay  
Full scale is ten divisions  
100 fs/div  
100 us/div  
Less than 10 ns. Time offset between the front panel  
clock input and the front panel channel input  
1 ps + 0.2% of the measured time interval while the  
delay settings is less that the absolute minimum delay  
plus 1 ns  
If the delay setting is greater than the absolute  
minimum delay plus 1 ns then the accuracy is 5 ps +  
0.1% of the measured time interval  
< 450 fs rms  
Time interval accuracy  
(Dual marker measurement performed at a  
temperature within ± 5 °C (± 41 °F)of horizontal  
calibration temperature)  
Jitter (Slew rate ≥ 2 V/ns)  
Option LOJ  
< 160 fs rms  
Time interval resolution  
(The time interval resolution is the smallest time  
you can characterize between two points)  
Display units  
(Screen diameter)/(Record length) or 40 fs, whichever  
is larger  
Bits or time  
Record length  
16 to 131,072 samples. Increments of 1  
Sample rate  
Sample rate does not change for multiple channel 100 kHz  
configurations  
Option FS1  
250 kHz  
N1092/4 Environmental Specifications  
Item  
Description  
Use  
Indoor  
Temperature  
Operating  
Non-operating  
Altitude (operating)  
Maximum relative humidity  
10 to +40 °C (50 to +104 °F)  
–40 to +70 °C (–40 to +158 °F)  
Up to 4,600 meters (15,000 ft)  
80% for temperatures up to 31 °C (87.8 °F) decreasing  
linearly to 50% relative humidity at 40 °C (104 °F)  
100/120 Vac  
Line power  
50/60/400 Hz  
220/240 Vac  
50/60 Hz  
290 W maximum  
The products can operate with mains supply voltage  
fluctuations up to ± 10% of the nominal voltage  
Weight  
Mainframe (characteristic)  
6.20 kg (13.68 lb)  
Without front connectors and rear feet (H x W x D) 88.26 mm x 207.40 mm x 485 mm  
(3.48 in x 8.17 in x 19.01 in)  
With front connectors and rear feet (H x W x D)  
With front cover and rear feet (H x W x D)  
103.31 mm x 219.56 mm x 517.80 mm  
(4.07 in x 8.64 in x 20.39 in)  
110.18 mm x 219.56 mm x 550.71 mm  
(4.34 in x 8.64 in x 21.68 in)  