欢迎访问ic37.com |
会员登录 免费注册
发布采购

M9393A-WB1 参数 Datasheet PDF下载

M9393A-WB1图片预览
型号: M9393A-WB1
PDF下载: 下载PDF文件 查看货源
内容描述: [M9393A PXIe Performance Vector Signal Analyzer]
分类和应用:
文件页数/大小: 39 页 / 3429 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号M9393A-WB1的Datasheet PDF文件第7页浏览型号M9393A-WB1的Datasheet PDF文件第8页浏览型号M9393A-WB1的Datasheet PDF文件第9页浏览型号M9393A-WB1的Datasheet PDF文件第10页浏览型号M9393A-WB1的Datasheet PDF文件第12页浏览型号M9393A-WB1的Datasheet PDF文件第13页浏览型号M9393A-WB1的Datasheet PDF文件第14页浏览型号M9393A-WB1的Datasheet PDF文件第15页  
11 | Keysight | M9393A PXIe Performance Vector Signal Analyzer – Data Sheet  
Technical Specifications and Characteristics  
Standard Configuration - Options F08, F14, F18, F27  
Amplitude (cont’d)  
Amplitude switching speed 27  
Option UNZ, nominal  
List mode switching speed  
From lower to higher power 28  
From higher to lower power 28  
Pre-amp OFF to pre-amp ON  
Pre-amp ON to pre-amp OFF  
Non-list mode switching speed  
Standard, nominal  
9 kHz to 3.6 GHz  
90 µs  
3.6 to 6 GHz  
180 µs  
6 to 27 GHz  
50 µs  
90 µs  
50 µs  
50 µs  
245 µs  
160 µs  
1 ms  
190 µs  
190 µs  
90 µs  
220 µs  
5 ms  
Input voltage standing wave ratio (VSWR)  
Pre-amp OFF, nominal  
< 1.38 : 1  
Pre-amp ON, nominal  
10 MHz to ≤ 50 MHz  
> 50 MHz to ≤ 3 GHz  
> 3 GHz to ≤ 3.6 GHz  
> 3.6 GHz to ≤ 12 GHz  
> 12 GHz to ≤ 20 GHz  
> 20 GHz to ≤ 23 GHz  
> 23 GHz to ≤ 27 GHz  
< 2.57 : 1  
< 1.9 : 1  
< 1.21 : 1  
< 1.12 : 1  
< 1.61 : 1  
< 1.4 : 1  
< 1.49 : 1  
< 1.99 : 1  
< 1.99 : 1  
< 1.36 : 1  
< 1.82 : 1  
< 1.36 : 1  
< 1.81 : 1  
Trace detectors  
With IVI driver  
Normal  
With 89600 VSA software  
Normal, Max, Sample, Average, Min  
Preamplifier  
Frequency range  
Option F08  
Option F14  
9 kHz to 8.4 GHz  
9 kHz to 14 GHz  
9 kHz to 18 GHz  
9 kHz to 27 GHz  
Typical  
Option F18  
Option F27  
Gain 29  
< 3.6 GHz  
+15.5 dB  
3.6 to < 15 GHz  
15 to < 25 GHz  
25 to 27 GHz  
+25.0 dB  
+22.0 dB  
+19.0 dB  
27. When using M9018A PXIe chassis (2-link configuration: 1 x 8 [factory default]) and M9037A PXIe embedded controller.  
Amplitude settled to within 0.1 dB. Does not include data acquisition or processing time.  
28. No pre-amplifier switching.  
29. Gain is normalized to pre-amplifier OFF state.  
 复制成功!