05 Keysight M9186A PXI Voltage/Current Source Data Sheet
Voltage Source Accuracy
Accuracy ± (% of output + offset)
1-year, 23 °C ± 5 °C
Range
Conditions
± 16 V
Up to 200 mA
0.02 % + 3 mV
Current Sense using the SENSE pin with respect 200 mA range: 1.5 % + 500 µA
to OUTPUT.
20 mA range: 0.5 % +50 µA
2 mA range: 0.5 % + 10 µA
200 µA range: 0.3 % + 5 µA
–10 to + 100 V
Up to 20 mA
0.02 % + 40 mV
0.75 % + 300 µA
Current Sense using the SENSE pin with respect
to OUTPUT.
Current Source Accuracy
Accuracy ± (% of output + offset)
1-year, 23 °C ± 5 °C
Range
Conditions
± 200 mA
± 20 mA
± 2 mA
Over ± 16 V
0.3 % + 500 μA
0.1 % + 50 μA
0.3 % + 5 μA
± 200 μA
± 20 mA
0.1 % + 0.5 μA
0.3 % + 500 µA
Over –10 to +100 Vdc
General Specifications
Description
Specification
Temperature Range
– Operating
0 º to 55 ºC
– Storage
–40 ºC to +70 ºC
Relative Humidity
80%, 0 ºC to 40 ºC (Non condensing)
Certifications and Compliance
Altitude : 10,000 ft (Operating)/15,000 ft (Non-operating)
2006/95/EC; 2004/108/EC
Pollution Degree 2
– CE Mark Compliance
– Safety
– EMC Immunity
– EMC Emissions
EN/IEC 61326-1 Industrial Environment
EN/IEC 61326-1 Class A
Warm-Up Time
30 minutes
PXI Power Requirements (typ)
6 W at 5 V, 3 W at 3.3 V, 1 W at 12 V
Additional Information
Recommended Calibration Interval
1 Year