09 | Keysight | N4917B Optical Receiver Stress Test Solution - Solution Brochure  
N4917B Detailed Test Setup  
After the calibration step, each lane of the DUT should be tested in turn, with valid signals  
present on the other lanes. Exact connection details and setup depend on the type of device  
being tested. A couple of examples are shown below.  
LR4 Transceiver Test  
In this example an optical de-multiplexer is used to bring out the four lanes on four individual  
fibers. Attenuators in each lane are used to set the relative optical modulation amplitude (OMA)  
with respect to the lane under test. The calibrated stressed eye signal is connected to the lane  
under test at the optical mulitplexer which combines all four lanes onto one fiber.  
BER measurement during the Jitter Tolereance test sweep can either be read from the device  
under test or optionally looped back to the BERT for fully automated JTOL testing.  
Data  
Generator 0  
TX 1  
Data  
Generator 1  
TX 2  
TX 3  
TX 4  
4-lane WDM SMF  
Data  
Generator 2  
Data  
Generator 3  
λ3  
λ3  
Optical  
Attenuator  
Error  
Checker 3  
RX 1  
RX 2  
λ2  
λ1  
λ0  
λ2  
λ1  
λ0  
Optical  
Attenuator  
Error  
Checker 2  
4-lane WDM  
SMF  
Optical  
Attenuator  
Error  
Checker 1  
RX 3  
RX 4  
Error  
Checker 0  
Optical  
Attenuator  
DUT 100GBASE-LR4 Transceiver  
Optional return  
path to BERT  
Calibrated  
Stressed Eye  
Signal  
Figure 7. Example 100GBASE-LR4 setup for running a stressed receiver sensitivity test on a device.