欢迎访问ic37.com |
会员登录 免费注册
发布采购

M8041A-0G3 参数 Datasheet PDF下载

M8041A-0G3图片预览
型号: M8041A-0G3
PDF下载: 下载PDF文件 查看货源
内容描述: [Optical Receiver Stress Test Solution]
分类和应用:
文件页数/大小: 21 页 / 2726 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号M8041A-0G3的Datasheet PDF文件第1页浏览型号M8041A-0G3的Datasheet PDF文件第2页浏览型号M8041A-0G3的Datasheet PDF文件第3页浏览型号M8041A-0G3的Datasheet PDF文件第4页浏览型号M8041A-0G3的Datasheet PDF文件第6页浏览型号M8041A-0G3的Datasheet PDF文件第7页浏览型号M8041A-0G3的Datasheet PDF文件第8页浏览型号M8041A-0G3的Datasheet PDF文件第9页  
05 | Keysight | N4917B Optical Receiver Stress Test Solution - Solution Brochure  
100GBASE-LR4/ER4/SR4 Optical Stressed Eye Test  
Challenges  
The IEEE 802.3 standard, clauses 88.7, 95.7 describe the optical specifications for  
100GBASE-LR4, -ER4 and -SR4 optical receivers. The following table contains the salient  
conditions required for stressed receiver sensitivity test.  
Parameter description  
100GBASE-LR4  
6.8 dBm  
4 dB  
100GBASE-ER4  
–17.9 dBm  
8 dB  
100GBASE-SR4  
–5.2 dBm  
2 dB  
Stressed receiver sensitivity (OMA), lane under test (max)  
Extinction ratio (with jitter and interferers off)  
Conditions of stressed receiver sensitivity test  
Vertical eye closure penalty (VECP), lane under test  
Stressed eye closure (SEC), lane under test  
Stressed eye J2 jitter, lane under test  
1.8 dB  
3.5 dB  
-
-
-
4.3 dB  
0.3 UI  
0.3 UI  
0.39 UI  
Stressed eye J4 jitter, lane under test  
-
0.47 UI  
-
-
0.47 UI  
-
0.53 UI  
Stressed eye J9 jitter, lane under test  
-
Stressed receiver eye mask definition {X1,X2,X3,Y1,Y2,Y3}  
Hit ratio 5E-5 hits per sample  
{0.28,0.5,0.5,0.33,0.33,0.4}  
Setting up a stressed eye according to the standard can be a very time consuming task, even  
for experienced users it can take a half day. The reason is that the stressed eye parameters  
are interdependent and therefore several iterations of the optimization cycle are required  
to converge on the solution. In addition, it is important that the setup is repeatable and  
remains stable from the time of the stressed eye calibration through to the end of the DUT  
measurement. Otherwise a drift in the test setup, especially in the electro-optical converter will  
impair the test results.  
The N4917B optical receiver stress test solution provides a repeatable and stable measurement  
in a fraction of time compared to manual setup of the stressed eye. This offers major time  
saving during daily measurements and speeds up developing a standard compliant test solution  
when compared to a self made solution.