Performance Characteristics (Continued)  
Acquisition system  
EDUX1002A/EDUX1002G  
1 GSa/s  
100 kpts  
DSOX1102A/DSOX1102G  
2 GSa/s  
1 Mpts  
Maximum sample rate  
Maximum analog channels  
record length  
Acquisition mode  
Normal  
Default mode  
Default mode  
Peak detect  
Capture glitches as narrow as 10 ns at all time  
base settings  
Capture glitches as narrow as 10 ns at all time  
base settings  
Capture glitches as narrow as 5 ns at all time  
base settings with 100 MHz bandwidth upgrade  
- DSOX1B7T102  
Averaging  
High resolution  
Selectable from 2, 4, 8, 16, 64, ... to 65,536  
Real-time boxcar averaging reduces random  
Selectable from 2, 4, 8, 16, 64, ... to 65,536  
Real-time boxcar averaging reduces random  
noise and effectively increases vertical resolution noise and effectively increases vertical resolution  
to 12 bits of resolution when ≥ 20 μs/div at  
2 GSa/s  
to 12 bits of resolution when ≥ 20 μs/div at  
2 GSa/s  
Segmented  
Not available  
Segmented memory optimizes available memory  
for data streams that have long dead times  
between activity. Maximum segments = 50.  
Re-arm time = 19 μs (minimum time between  
trigger events)  
Time mode  
Normal  
Roll  
Default mode  
Default mode  
Displays the waveform moving across the screen Displays the waveform moving across the screen  
from right to left. Available at the time base  
50 ms/div or slower  
from right to left. Available at the time base  
50 ms/div or slower  
XY  
Displays the volts-versus-volts display  
X = Channel 1, Y = Channel 2  
Displays the volts-versus-volts display  
X = Channel 1, Y = Channel 2  
Z = External trigger, 1.4 V blanking  
Phase error at 1 MHz: < 0.5 degree  
Finds and displays all active channels and  
external trigger. Sets edge trigger mode on  
external trigger first then highest numbered  
Z = External trigger, 1.4 V blanking  
Phase error at 1 MHz: < 0.5 degree  
Finds and displays all active channels and  
external trigger. Sets edge trigger mode on  
external trigger first then highest numbered  
Autoscale  
active channel. Sets vertical sensitivity. Sets time active channel. Sets vertical sensitivity. Sets time  
base to display ~ 1.8 periods. Requires minimum base to display ~ 1.8 periods. Requires minimum  
voltage of 10 mVpp (channel)  
voltage of 10 mVpp (channel)  
 复制成功!